P9PDNVL GE, P9PDNVL Datasheet - Page 60

no-image

P9PDNVL

Manufacturer Part Number
P9PDNVL
Description
FULL VOLTAGE
Manufacturer
GE
Datasheet

Specifications of P9PDNVL

Screw
INCAND
Accessory Type
Power Supply
For Use With
C-2000 Series Contactors & Starters
Front-Mount Auxiliary Contact Blocks
Side-Mount Auxiliary Contact Blocks
Front-mount auxiliary contact blocks clip onto front face of control relay. Contact rating: A600 Q600.
Instantaneous, Front-Mounted
Contact Ratings
Note: For DC ratings at 600 Volts or less, the make and break ratings
shall be obtained by dividing the voltampere rating by the application
voltage but shall not exceed the continuous carrying current.
The DC rating shown in the above table shall not be exceeded when
applied to control circuit devices.
Side-mount auxiliary contact blocks can be mounted on either left or right sides of control relay. Positive displacement contacts
are designed to prevent simultaneous closing of NO and NC contacts to avoid overlapping between opposing functions.
Contact rating: A600 Q600.
* Maximum of two side-mount auxiliary contact blocks per side of con-
trol relay.
Contact Ratings
Note: For DC ratings at 600 Volts or less, the make and break ratings
shall be obtained by dividing the voltampere rating by the application
voltage but shall not exceed the continuous carrying current.
The DC rating shown in the above table shall not be exceeded when
applied to control circuit devices.
Type
Standard
Make Before Break
(Overlapping Contacts)
Continuous Thermal
Max. VA/Amps Making
Max. VA/Amps Breaking
Max. Operating Voltage
Continuous Thermal
Max. VA/Amps Making
Max. VA/Amps Breaking
Max. Operating Voltage
BCLF10
Current
Current
BRLL11
Contacts*
1NO-1NC
2NO
BCLF01
BRLL20
7200 VA / 60 A
Adder Block
7200 VA / 60 A
Contacts
720 VA / 6 A
720 VA / 6 A
BRLL11
BRLL20
600 VAC
600 VAC
1NO
1NC
1NO
1NC
A600
10 A
A600
10 A
BCLF10G
BCLF10G
BCLF01G
BCLF10
BCLF01
Catalog
600 VDC
600 VDC
No.
69 VA
69 VA
69 VA
69 VA
Q600
2.5 A
Q600
2.5 A
BCLF01G
Weight
2 oz.
2 oz.
Weight
.5 oz.
.5 oz.
.5 oz.
.5 oz.
Control Relay Accessories
Front-Mount Auxiliary Contact Block Specifications
Rated thermal current
Rated insulation voltage
Making capacity (r.m.s.) in accordance with IEC 947
Breaking capacity (r.m.s.) in accordance with IEC 947
Electrical (AC-3) endurance at
Insulation resistance
Standard Instantaneous Contacts
Side-Mount Auxiliary Contact Block Specifications
Rated thermal current
Rated insulation voltage
Making capacity (r.m.s.) in accordance with IEC 947
Breaking capacity (r.m.s.) in accordance with IEC 947
Electrical (AC-3) endurance at
Insulation resistance
Standard Instantaneous Contacts
(Ith) temperature below 55°C. . . . . . . . . . . . . . 10A
(Ui) in accordance with IEC 947 . . . . . . . . . . . 1000V
AC 15/AC 11, Ue
DC 13/DC 11, Ue
AC 15/AC 11, Ue
DC 13/DC 11, Ue
rated current (millions of operations) . . . . . 1.0
Between contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . > 10 M
Between contacts and earth . . . . . . . . . . . . . . . . > 10 M
Between input and output. . . . . . . . . . . . . . . . . . > 10 M
Guaranteed no overlap between NO and NC contacts
(Ith) temperature below 55°C ......................10A
(Ui) in accordance with IEC 947 ..................1000V
AC 15/AC 11, Ue
DC 13/DC 11, Ue
AC 15/AC 11, Ue
DC 13/DC 11, Ue
rated current (millions of operations) .........1.0
Between contacts ...........................................> 10 M
Between contacts and earth ..........................> 10 M
Between input and output ............................> 10 M
Guaranteed no overlap between NO and NC contacts
Space. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 mm
Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 ms
Space .........................................................1.3 mm
Time ..........................................................1.5 ms
400V, 50/60 Hz. . . . . . . . 60A
400V, 50/60 Hz ...........90A
400V, 50/60 Hz ............60A
220V DC . . . . . . . . . . . . . . 90A
220V DC . . . . . . . . . . . . . . 0.95A
220V DC .......................90A
220V DC .......................0.95A
400V, 50/60 Hz . . . . . . . 90A
C-2000
Contactors & Starters
59