C500CP131 Omron, C500CP131 Datasheet - Page 233

no-image

C500CP131

Manufacturer Part Number
C500CP131
Description
C-SERIES SPECIAL I/O UNIT
Manufacturer
Omron
Datasheet

Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
PC Setup
228
PC Setup Default Settings
Letter
Letter
M
S
A
B
C
D
E
G
H
K
N
P
Q
T
F
L
J
I
Error log area
Display modes at startup
(IOIF, RT display)
Holding bits
(Hold areas)
Startup hold
Startup mode
Startup processing
I/O refresh
Execution controls 1
(Execute control 1)
Execution controls 2
(Execute control 2)
Host link
CPU bus links
Scheduled interrupt interval
First words for local racks
(1st Rack addr)
First words for group-1 and
group-2 Slaves (Group 1,2 1st
addr)
First words for I/O Terminals
(Trans I/O addr)
First words for group-3 Slaves
(Group 3 RT 1st adds)
Momentary power interruption
time (Power break)
Cycle time
Name
Name
Designate the size and range of the error log. When a error occurs,
information about the error is saved in this memory area together with the
time that the error occurred. Refer to the CV500/CV1000 Operation Manual:
Ladder Diagrams for details about the error log. This setting is effective the
next time the power is turned ON.
(Default: 20 records of 5 words each in A100 to A199)
Designate the display mode to be used for the 7-segment displays on I/O
Interface Units, the I/O Control Unit, and SYSMAC BUS/2 Remote I/O Slave
Units when the power is turned ON. This setting is effective the next time the
power is turned ON.
(Default: Mode 1)
Hold area:
Holding Racks: Nothing held
Forced Status Hold Bit: Not held
IOM Hold Bit:
Restart Continuation Bit: Not held
PROGRAM
User program not transferred.
Cyclic refresh
Detect low battery:
Power interruption:
CPU standby:
CPU-bus Unit cycle: Not measured
CPU operation:
us
I/O interrupts:
interrupts
Power OFF interrupt: Disable
Dup action process: Error
Baud rate:
Stop bits:
Parity:
No CPU bus links
10 ms
CPU Rack: 0000
Others:
Group 1
Group 2
RM &0
RM &7
2300
2524
Group-3 Slaves (SYSMAC BUS/2)
RM #0
0300
SYSMAC BUS Systems
RM #0 to RM #7 defaults are identical to those for I/O Terminals, above.
0 ms
Variable cycle
RM #1
0500
RM &1
2332
RM &0
0200
0250
None
9,600 bps
2
Even
CIO 1200 to CIO 1499
Fatal
Detect
CPU waits (RUN waits)
Asynchrono
Nesting
RM #2
0700
RM &2
2364
RM &1
0400
0450
Not held
Default setting
Operation
RM #3
0900
RM &3
2398
RM &2
0600
0650
Step timer:
increments
Startup trace:
Indirect DM:
Comparison error:
Data length: 7
Unit number: 00
RM &3
0800
0850
RM &4
2428
RM &5
2460
Section 7-2
0.1 s
No
BCD
RUN
RM &6
2492