MCR-C-UI-UI-DCI-NC Phoenix Contact, MCR-C-UI-UI-DCI-NC Datasheet - Page 8

no-image

MCR-C-UI-UI-DCI-NC

Manufacturer Part Number
MCR-C-UI-UI-DCI-NC
Description
INTERFACE ANALOG
Manufacturer
Phoenix Contact
Datasheet

Specifications of MCR-C-UI-UI-DCI-NC

Input Type
Configurable
Output Type
Configurable
No. Of Output Channels
1
Accuracy
± 0.1%
Supply Voltage Range
18VDC To 30VDC
Approval Bodies
CE, GL, UL Recognised
External Depth
114.5mm
External Length /
RoHS Compliant
External Length / Height
99mm
Rohs Compliant
Yes
Signal Conditioner Input
0V To 10V
Signal Conditioner Output
0V To 10V
100238_en_02
Configuration
Adjustment
DIP 1
HYBRID TV1
PHOENIX CONTACT
DIP 2
If the modules are not configured (all DIP switches set to
pos. 0), the module does not have a defined function until the
DIP switches have been set.
DIP switches S1 and S2 specify the combination of input and
output standard signal ranges (see configuration table).
Standard Configuration
"NC" versions (...-NC) have the following standard configura-
tion:
(All DIP switches are set to the "OFF" position)
Opening the Module
Using a screwdriver, release the locked upper part of the
housing on both sides. The upper part of the housing and the
electronics can now be pulled out approximately 3 cm.
The "ZERO" potentiometer is used to adjust the zero point of
the module and the "SPAN" potentiometer is used to adjust
the final value. Both potentiometers are located on the top of
the module.
0 ... 10 V input
0 ... 10 V output
CAUTION: Electrostatic discharge
The module contains components that can be
damaged or destroyed by electrostatic di-
scharge. When handling the module, observe
the necessary safety precautions against elec-
trostatic discharge (ESD) according to EN
61340-5-1 and EN 61340-5-2.
ATTENTION: Module can become damaged
Before commencing the adjustment process,
observe the warm-up phase of two minutes.
MCR-C-UI-UI(-450)-DCI(-NC)
PHOENIX CONTACT
8

Related parts for MCR-C-UI-UI-DCI-NC