AD5560JSVUZ-REEL Analog Devices Inc, AD5560JSVUZ-REEL Datasheet - Page 30

no-image

AD5560JSVUZ-REEL

Manufacturer Part Number
AD5560JSVUZ-REEL
Description
1.2A Programmable DPS With DACs
Manufacturer
Analog Devices Inc
Type
Power Supplyr
Datasheet

Specifications of AD5560JSVUZ-REEL

Design Resources
Integrated Device Power Supply for PAD with Output Voltage Range 0 V to 25 V (CN0130)
Applications
Automatic Test Equipment
Mounting Type
Surface Mount
Package / Case
64-TQFP Exposed Pad, 64-eTQFP, 64-HTQFP, 64-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5560JSVUZ-REEL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD5560JSVUZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD5560
Master in FV Mode, Slaves in Force Current (FI) Mode
The master device is placed into FV mode, and all slave devices
into force current (FI) mode. The measured current of the
master device (MASTER_OUT) is applied to the input of all
slave devices (SLAVE_IN), and the slaves act as followers. All
channels work to share the current equally among all devices
in the gang. Because the slaves force current, matching the
DUT paths is not so critical. Settings for DPS Register 2 are
master = 0x0200, slave = 0x0600. Clamps should be disabled in
the slave devices.
MASTER DPS
SLAVE DPS 1
SLAVE DPS 2
MEASOUT
AND GAIN
MEASOUT
AND GAIN
MEASOUT
AND GAIN
DAC
DAC
DAC
FIN
BUFFER
FIN
BUFFER
FIN
BUFFER
SW16
SW16
SW16
Figure 53. Simplified Block Diagram of Gang Mode,
Using an FV/FI Combination
I
I
I
SENSE
SENSE
SENSE
AMP
AMP
AMP
SW5-a
SW5-a
SW5-a
SW5-b
SW5-b
SW5-b
SW5-a
SW5-a
SW5-a
×20
×20
×20
MASTER OUT
MASTER OUT
MASTER OUT
EXTMEASIH1
EXTMEASIH1
EXTMEASIH1
SW6
SW6
SW6
EXTFORCE1
EXTFORCE2
EXTMEASIL
EXTFORCE1
EXTFORCE2
EXTMEASIL
EXTFORCE1
EXTFORCE2
EXTMEASIL
SLAVE IN
SLAVE IN
SLAVE IN
SENSE
SENSE
SENSE
DUTGND
R
SENSE
DUT
Rev. C | Page 30 of 60
The EXTFORCE1, EXTFORCE2, or ±25 mA ranges can be
used for the gang mode. Therefore, it is possible to gang devices
to get a high voltage/high current combination, or a low
voltage/high current combination.
For example, ganging five 25 V/25 mA devices using the 25 mA
range achieves a 25 V/625 mA range, whereas five 15 V/200 mA
devices using the EXTFORCE2 path can achieve a 15 V/1 A
range. Similarly, ganging four 3.5 V/1.2 A devices using the
EXTFORCE1 path results in a 3.5 V/4.8 A DPS.
IDEAL SEQUENCE FOR GANG MODE
Use the following steps to bring devices into and out of gang mode:
1.
2.
3.
4.
5.
To remove devices from the gang, the master device should
be programmed to force 0 V out again. The procedure for
removing devices should be the reverse of Step 1 through Step 5.
Note that this may not always be possible in practice; therefore,
it is also possible to gang and ungang while driving a load. Just
ensure that the slave devices are in high-Z mode while confi-
guring them into the required range and gang setting.
Gang mode extends only to the ±25 mA range and the two high
current ranges, EXTFORCE1 and EXTFORCE2. Therefore, where
an accurate measurement is required at a low current, the user
should remove slaves from the gang to move to the appropriate
lower current range to make the measurement. Similarly, slaves
can be brought back into the gang if needed.
COMPENSATION FOR GANG MODE
When ganging, the slave devices should be set to the fastest
response.
When slaves are in FI mode, the AD5560 force amplifier over-
rides other compensation settings to enforce C
and g
therefore, readback will not show that the signals inside the
force amplifier actually change.
SYSTEM FORCE/SENSE SWITCHES
System force/sense switches allow easy connection of a central
or system parametric measurement unit (PMU) for calibration
or additional measurement purposes.
The system device under test ground (SYS_DUTGND) switch
is shared with the GUARD/SYS_DUTGND pin (Pin 43). See
the DPS Register 2 in Table 19 for addressing details.
Choose the master device and force 0 V output, corres-
ponding to zero current.
Select slave DPS 1 and place it in slave mode (keep slaves in
high-Z mode via SW-INH or HW_INH until ready to gang).
Select to gang in either current or voltage mode.
Repeat Step 2 and Step 3 one at a time through the chain of
slaves.
Load the required voltage to the master device. The other
devices copy either voltage or current as programmed.
mx
≤ 1. This is done internally to the force amplifier;
Fx
= 0, R
Z
= 0,

Related parts for AD5560JSVUZ-REEL