Specifications of ADUC814BRU

Peak Reflow Compatible (260 C)
No
No. Of Bits
12 Bit
Leaded Process Compatible
No
Mounting Type
Surface Mount
No. Of Inputs
6
Features
+3V Or +5V Operation
Package / Case
28-TSSOP
Rohs Status
RoHS non-compliant
Core Processor
8052
Core Size
8-Bit
Speed
16.78MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
POR, PSM, Temp Sensor, WDT
Number Of I /o
17
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Eeprom Size
640 x 8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 6x12b; D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
EVAL-ADUC814QSZ - KIT DEV FOR ADUC814 MICROCONVRTR
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUC814BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuC814
INTVAL
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
HTHSEC
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
SEC
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
MIN
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
HOUR
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
User Time Interval Select Register
User code writes the required time interval to this register. When the 8-bit interval counter is equal to the time
interval value loaded in the INTVAL SFR, the TII bit (TIMECON.2) is set and generates an interrupt if enabled.
(See the IEIP2 SFR description in the Interrupt System section.)
A6H
00H
No
0 to 255 decimal
Hundredths Seconds Time Register
This register is incremented in 1/128 second intervals once TCEN in TIMECON is active. The HTHSEC SFR
counts from 0 to 127 before rolling over to increment the SEC time register.
A2H
00H
No
0 to 127 decimal
Seconds Time Register
This register is incremented in 1-second intervals once TCEN in TIMECON is active. The SEC SFR counts from
0 to 59 before rolling over to increment the MIN time register.
A3H
00H
No
0 to 59 decimal
Minutes Time Register
This register is incremented in 1-minute intervals once TCEN in TIMECON is active. The MIN SFR counts
from 0 to 59 before rolling over to increment the HOUR time register.
A4H
00H
No
0 to 59 decimal
Hours Time Register
This register is incremented in 1-hour intervals once TCEN in TIMECON is active. If the TFH bit (TIMECON.6)
is set to 1 the HOUR SFR counts from 0 to 23 before rolling over to 0. If the TFH bit is set to 0, the HOUR SFR
counts from 0 to 255 before rolling over to 0.
A5H
00H
No
0 to 23 decimal
Rev. A | Page 40 of 72