MTCBA-H4-EN2-GP-P2 Multi-Tech Systems, MTCBA-H4-EN2-GP-P2 Datasheet - Page 10

no-image

MTCBA-H4-EN2-GP-P2

Manufacturer Part Number
MTCBA-H4-EN2-GP-P2
Description
ROUTER WIRELESS QUAD HSPA
Manufacturer
Multi-Tech Systems
Series
MultiModem® rCellr
Datasheets

Specifications of MTCBA-H4-EN2-GP-P2

Function
Transceiver, HSPA, Router
Modulation Or Protocol
GPRS, GSM, EDGE
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz, 1575.42MHz
Applications
AT&T Networks (USA)
Interface
RJ-45, RS-232
Sensitivity
-161dB
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1090
Summary of GSM/WCDMA Commands Described in
This Document
ITU-T Recommendation V.250 AT Commands
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A)
The following AT Commands (ITU-T Recommendation V.250, 3GPP TS 27.005, and 3GPP TS 27.007) are
supported on the Multi-Tech SocketModem Cell, SocketModem iCell, and MTSMC-H4 Embedded Cellular
Modems. These commands are used to:
The table below indicates whether or not each command is supported on the H4 modems.
Supported commands are described in Chapter 3.
Command
&C
&D
&F
&S
&T
&W
+DR
+DS
+GCAP
+GMI
+GMM
+GMR
+GOI
+GSN
+ICF
+IFC
+ILRR
+IPR
A
D
D><MEM><N>
D><N>
D><STR>
DL
E
H
I
L
M
O
P
Control serial communications over an asynchronous interface (ITU-T Recommendation V.250)
Control SMS functions for devices on GSM/WCDMA networks (3GPP TS 27.005)
Control devices operating on GSM/WCDMA networks (3GPP TS 27.007)
Description
Set Data Carrier Detected (Received line signal detector) function
mode
Set Data Terminal Ready function mode
Set all current parameters to manufacturer’s defaults
Set DSR signal
Auto tests
Store current parameter to user-defined profile
V42bis data compression report
V42bis data compression
Request complete TA capabilities list
Request manufacturer identification
Request TA model identification
Request TA revision identification
Request global object identification
Request TA serial number identification
Set TE-TA control character framing
Set TE-TA local data flow control
Set TE-TA local rate reporting mode
Set fixed local rate
Answer incoming call
Dial
Originate call to phone number in memory <MEM>
Originate call to phone number in current memory
Originate call to phone number in memory which corresponds to
alphanumeric field <STR>
Redial last telephone number used
Set command echo mode
Disconnect existing connections
Display product identification information
Set monitor speaker loudness
Set monitor speaker mode
Switch from command mode to data mode
Select pulse dialing
Chapter 1– Introduction
Supported
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
No
No
Yes
No
10