MTCBA-H4-EN2-GP-P2 Multi-Tech Systems, MTCBA-H4-EN2-GP-P2 Datasheet - Page 102

no-image

MTCBA-H4-EN2-GP-P2

Manufacturer Part Number
MTCBA-H4-EN2-GP-P2
Description
ROUTER WIRELESS QUAD HSPA
Manufacturer
Multi-Tech Systems
Series
MultiModem® rCellr
Datasheets

Specifications of MTCBA-H4-EN2-GP-P2

Function
Transceiver, HSPA, Router
Modulation Or Protocol
GPRS, GSM, EDGE
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz, 1575.42MHz
Applications
AT&T Networks (USA)
Interface
RJ-45, RS-232
Sensitivity
-161dB
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1090
+CHUP Hang Up Call
+CIMI Request IMSI
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A)
Description:
Syntax:
Test Command:
Test Response:
Exec. Command: AT+CHUP
Exec. Response: OK
Note:
Description:
Syntax:
Values:
Parameter Storage:
Examples:
This command reads and identifies the IMSI (International Mobile Subscriber Identity) of the
SIM card.
No Read and Test Commands
<IMSI>
Command
Action Command:
AT+CIMI
Command
AT+CIMI
Note: Read the IMSI
Cancels all active, waiting, and held calls. (Not applicable at this time)
AT+CHUP=?
OK
ERROR
+CME ERROR <err>
ERROR
+CME ERROR <err>
AT+CHUP supports only voice calls. Data connections can be disconnected with ATH
only.
IMSI of SIM Card
15 digit number
None
Response
<IMSI>
OK
Responses
208200120320598
OK
Note: IMSI value (15 digits), starting with MCC
(3 digits) / MNC (2 digits, 3 for PCS 1900)
Chapter 3 – Supported GSM/WCDMA AT Commands
102