Specifications of MTCBA-H4-EN2-GP-P2

Function
Transceiver, HSPA, Router
Modulation Or Protocol
GPRS, GSM, EDGE
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz, 1575.42MHz
Applications
AT&T Networks (USA)
Interface
RJ-45, RS-232
Sensitivity
-161dB
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1090
S6 Set Pause Before Blind Dialing
S7 Set Number of Seconds to Wait for Connection
S8 Set Number of Seconds to Wait When Comma Dial
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A)
Description:
Syntax:
Parameter Description:
Description:
Syntax:
Values:
Description:
Syntax:
Parameter Description:
Completion
Modifier Is Used
Read Command:
Read Response:
Write Command:
Write Response:
<n>
Read Command:
Read Response:
Write Command:
Write Response:
<n>
0
1...255
002 – 10 Default is 002
No effect for GSM.
This command defines the maximum time allowed between completion of dialing and the
connection being established. If this time is exceeded, then the connection is aborted. The
value is not persistent.
Command syntax: ATS7=<value>
<value>
This command specifies the amount of time, in seconds, that the DCE shall pause, during
signaling of call addressing information to the network (dialing), when a “,” (comma) dial
modifier is encountered in a dial string. No effect for GSM.
1 – 255
Command
ATS7=100
Timeout in seconds
Default value is 50
ATS6?
<n>
OK
ATS6=<n>
OK
ERROR
ATS8?
<n>
OK
ATS8=<n>
OK
ERROR
DCE does not pause when “,” encountered in dial string.
Default = 2. Number of seconds to pause
Possible Responses
OK