H3DS-SL AC24-230/DC24-48 Omron, H3DS-SL AC24-230/DC24-48 Datasheet - Page 32

17.5mm TIMER DIN. MNT.

H3DS-SL AC24-230/DC24-48

Manufacturer Part Number
H3DS-SL AC24-230/DC24-48
Description
17.5mm TIMER DIN. MNT.
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of H3DS-SL AC24-230/DC24-48

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 120 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 230VAC, 24 ~ 48VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.1 s to 120 Hrs
Supply Voltage
24 V to 230 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DSSLAC24230DC2448
Z2395
H3DS-G
I
I
Setting of Selector
The selectors can be turned clockwise and counterclockwise to
select the desired time scale, or operating mode.
Each selector has a snap mechanism that secures the selector at
a given position. Set the selector at a position at which it is
secured. Do not set it midway between two securing positions or a
malfunction could result from improper setting.
Selection of Time Unit and Time Scale
The star-delta transfer time and star operation time scale are set
with the same selector. The star-delta transfer time can be set to
0.05, 0.1, 0.5, or 1. The star operation time scale can be set to a
multiplication factor of 1 or 10. If the star-delta transfer time is dis-
played in the display window in white letters, this means that the
star operation time scale is “x10”. Refer to the example below.
I
Note: The reset time requires a maximum of 0.5 s.
Inputs
Outputs
I/O Functions
Basic Operation
Timing Charts
Star-delta transfer time
Star-delta transfer time and
star operation time scale
display window and selector
0.05 s
0.05 s
0.1 s
0.5 s
0.1 s
0.5 s
1 s
1 s
Power (A
Star contact
17 and 18
(star indicator)
Delta contact
27 and 28
(delta indicator)
1
Control output
and A
2
)
ON
OFF
ON
OFF
ON
OFF
Star operation time scale
t
t
1
2
: Star operation time setting
: Star-delta transfer time
t
1
x10
x1
Star output is turned OFF when the dial set value is reached and delta output is ON
---
after the preset transfer time elapses
t
2
0.5 s
Time Setting
The star operation time of the Timer is set with the time setting
dial.
Locking/Unlocking of Selectors and Time Setting Dial
The time setting dial and time scale selector can be locked using
the Y92S-38 Lock Key, a special pen type tool that is sold sepa-
rately. To lock the dial or selectors, insert the Lock Key in the key-
hole to the lower right of the dial or selector and turn it clockwise
until the dial or selector is completely covered with the red cover.
To unlock, turn the Lock Key in the opposite direction.
Key hole
H3DS-G