H3DS-SL AC24-230/DC24-48 Omron, H3DS-SL AC24-230/DC24-48 Datasheet - Page 9

17.5mm TIMER DIN. MNT.

H3DS-SL AC24-230/DC24-48

Manufacturer Part Number
H3DS-SL AC24-230/DC24-48
Description
17.5mm TIMER DIN. MNT.
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of H3DS-SL AC24-230/DC24-48

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 120 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 230VAC, 24 ~ 48VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.1 s to 120 Hrs
Supply Voltage
24 V to 230 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DSSLAC24230DC2448
Z2395
H3DS
Timing Chart - continued from the previous page
Note: 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s.
Note: The start input of the H3DS-ML@ model is activated by applying a voltage to B1 and A2 terminals.
Operating
mode
D:
Signal
OFF-delay
E: Interval
G:
Signal
ON/OFF-
delay
J:
One-shot
output
(ON delay)
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).
Timing chart
Output relay: NC
15 and 16
Output relay: NO
(output indicator)
15 and 18
Power (A
Start (B
(see note)
Output relay: NC
15 and 16
Output relay: NO
(output indicator)
15 and 18
Power indicator
Power (A
Start (B
(see note)
Output relay: NC
15 and 16
Output relay: NO
(output indicator)
15 and 18
Power indicator
Power (A
Start (B
(see note)
Output relay: NC
15 and 16
Output relay: NO
(output indicator)
15 and 18
Power indicator
Power (A
Start (B
(see note)
Power indicator
1
1
1
1
1
1
1
1
and A
and A
and A
and A
and A
and A
and A
and A
2
2 )
2
2
)
)
)
2
2
2
2
)
)
)
)
Approx.
1
(fixed)
±
0.6 s
t
t
t t
Approx.
1
(fixed)
±
0.6 s
t
t
t-a
.
t-a
t-a
t-a
t-a
Approx.
1
(fixed)
t
t-a
±
0.6 s
t
t
t-a
Output
Output
Power
Power
Output
Power
Start
Basic operation
* Start input is valid and re-triggerable while the
Start
Output
*
Power
Start
Start
*
* For power-on operation, impose voltage to the
** Start input is valid and re-triggerable while the
* Start input is valid and re-triggerable while the
* For power-on operation, impose voltage to the
** Start input is valid and re-triggerable while the
Timer is in operation.
Basic operation
Basic operation
Basic operation
Start input. The Timer starts operating at the
moment the power is turned on.
Timer is in operation.
Timer is in operation.
Start input. The Timer starts operating at the
moment the power is turned on.
Timer is in operation.
**
**
t
*
*
t
t
t
t
Approx. 1
(fixed)
t
±
0.6 s
H3DS
t

Related parts for H3DS-SL AC24-230/DC24-48