M48T86MH1 STMicroelectronics, M48T86MH1 Datasheet - Page 18

Real Time Clock USE 511-M48T86MH1E

M48T86MH1

Manufacturer Part Number
M48T86MH1
Description
Real Time Clock USE 511-M48T86MH1E
Manufacturer
STMicroelectronics
Datasheet

Specifications of M48T86MH1

Function
Clock, Calendar, Interrupt, Alarm
Rtc Memory Size
128 B
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Multiplexed
Package / Case
SO-28
Time Format
HH:MM:SS, Binary
Date Format
DW:DM:M:Y, Binary
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M48T86MH1
Manufacturer:
CARTYS
Quantity:
2 585
Part Number:
M48T86MH1
Manufacturer:
ST
Quantity:
1 000
Part Number:
M48T86MH1
Manufacturer:
ST
0
Part Number:
M48T86MH1
Manufacturer:
ST
Quantity:
20 000
Part Number:
M48T86MH1/01
Manufacturer:
ST
0
Part Number:
M48T86MH1F
Manufacturer:
ST
0
Clock operations
3.9
18/36
should avoid interrupt service routines that would cause the time needed to read valid
time/calendar data to exceed 244 µs.
The third method uses a periodic interrupt to determine if an update cycle is in progress.
The UIP bit is set high between the setting of the PF bit (Register C; Bit 6). Periodic
interrupts that occur at a rate greater than t
reached at each occurrence of the periodic interrupt.The READs should be completed
within 1/(t
Square wave output selection
Thirteen of the 15 divider taps are made available to a 1-of-15 selector, as shown in the
block diagram of
square wave output signal on the SQW pin. The RS3-RS0 bits in Register A establish the
square wave output frequency. These frequencies are listed in
SQW frequency selection shares the 1-of-15 selector with the periodic interrupt generator.
Once the frequency is selected, the output of the SQW pin can be turned on and off under
program control with the Square Wave Enabled (SQWE) bit.
Table 4.
RS3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
PL/2
Square wave frequency/periodic interrupt rate
+ t
RS2
Register A bits
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
BUC
Figure 4 on page
) to ensure that data is not read during the update cycle.
RS1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
8. The purpose of selecting a divider tap is to generate a
RS0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
BUC
Frequency
8.192
4.096
2.048
1.024
allow valid time and date information to be
None
256
128
512
256
128
64
32
16
8
4
2
Square wave
Units
kHz
kHz
kHz
kHz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Table 4 on page
976.5625
1.953125
3.90625
122.070
244.141
488.281
3.90625
Period
7.8125
7.8125
15.625
Periodic interrupt
31.25
None
62.5
125
250
500
18. The
Units
M48T86
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
us
us
us
us

Related parts for M48T86MH1