LAN9312-NU SMSC, LAN9312-NU Datasheet - Page 138

Ethernet ICs Hi Per 2 Port 10/100 Ethernet Switch

LAN9312-NU

Manufacturer Part Number
LAN9312-NU
Description
Ethernet ICs Hi Per 2 Port 10/100 Ethernet Switch
Manufacturer
SMSC
Type
Two Port Managed Ethernet Switchr
Datasheet

Specifications of LAN9312-NU

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Switches
Number Of Transceivers
1
Standard Supported
802.3, 802.3u
Data Rate
10 Mbps, 100 Mbps
Supply Voltage (max)
3.3 V
Supply Voltage (min)
0 V
Supply Current (max)
185 mA, 295 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9312-NU
Manufacturer:
Microchip Technology
Quantity:
10 000
Revision 1.7 (06-29-10)
10.2.1
EEPROM Controller Operation
I
(E2P_CMD)
In Microwire EEPROM mode, the following operations are supported:
Note: In I
Note: The EEPROM Loader uses the READ command only.
The supported commands of each mode are detailed in
Register (E2P_CMD)," on page
Microwire) are explained in
respectively.
When issuing a WRITE, or WRAL command, the desired data must first be written into the
Data Register
EPC_COMMAND field of the
value. If the operation is a WRITE, the EPC_ADDRESS field in the
(E2P_CMD)
bit of the
when the EPC_BUSY bit is cleared.
When issuing a READ command, the EPC_COMMAND and EPC_ADDRESS fields of the
Command Register (E2P_CMD)
address, respectively. The READ command is executed by setting the EPC_BUSY bit of the
Command Register
bit is cleared, at which time the data from the EEPROM may be read from the
(E2P_DATA).
Other EEPROM operations (EWDS, EWEN, ERASE, ERAL, RELOAD) are performed by writing the
appropriate command into the EPC_COMMAND field of the
(E2P_CMD). The command is executed by setting the EPC_BUSY bit of the
Register
modifying the
Note: The EEPROM device powers-up in the erase/write disabled state. To modify the contents of
If an operation is attempted and the EEPROM device does not respond within 30mS, the LAN9312
will time-out, and the EPC_TIMEOUT bit of the
2
C and Microwire master EEPROM operations are performed using the
ERASE (Erase Location)
ERAL (Erase All)
EWDS (Erase/Write Disable)
EWEN (Erase/Write Enable)
READ (Read Location)
WRITE (Write Location)
WRAL (Write All)
RELOAD (EEPROM Loader Reload - See
are supported.
the EEPROM, the EWEN command must first be issued.
EEPROM Command Register (E2P_CMD)
(E2P_CMD). In all cases, the software must wait for the EPC_BUSY bit to clear before
2
C EEPROM mode, only a sub-set of the above commands (READ, WRITE, and RELOAD)
must also be set to the desired location. The command is executed when the EPC_BUSY
and
EEPROM Command Register
(E2P_DATA). The WRITE or WRAL command may then be issued by setting the
EEPROM Data Register
(E2P_CMD). The completion of the operation is indicated when the EPC_BUSY
Section 10.2.2, "I2C EEPROM"
High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface
EEPROM Command Register (E2P_CMD)
must be configured with the desired command value and the read
197. Details specific to each EEPROM controller mode (I
DATASHEET
138
(E2P_DATA).
(E2P_CMD).
Section 10.2.4, "EEPROM
EEPROM Command Register (E2P_CMD)
is set. The completion of the operation is indicated
and
Section 14.2.4.1, "EEPROM Command
Section 10.2.3, "Microwire EEPROM"
EEPROM Command Register
EEPROM Command Register
EEPROM Command Register
Loader")
to the desired command
EEPROM Data Register
EEPROM Command
SMSC LAN9312
will be set.
EEPROM
EEPROM
EEPROM
Datasheet