66102 EATON POWERWARE/MGE OFFICE PROTECTION, 66102 Datasheet - Page 22

Network Management Card

66102

Manufacturer Part Number
66102
Description
Network Management Card
Manufacturer
EATON POWERWARE/MGE OFFICE PROTECTION
Datasheet

Specifications of 66102

For Use With
Central UPS Systems That Protect A Complete Network Or For UPS Systems Providing Back-up For Critical Equipment

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
66102-8
Manufacturer:
TE
Quantity:
20 000
Part Number:
66102-8
Manufacturer:
yazaki
Quantity:
17 000
Part Number:
66102-9
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
48 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
35 000
The first shutdown criteria initiates the restart of the
For the controlled outlets ("group 1 or group 2" by default)
The page enables programming of operation time and level in backup mode to manage outlet load shedding in the event of electric power
failure:
Export settings to file: Enables exportation ("Download" button) and saving of card configuration information.
Import settings from file: Enables selection of a configuration file ("Browse" button) and uploading ("Upload" button) of card configuration
information
Security: The administrator has to click on Save and enter his/her login/password to save any modifications. The login and password by
default are: MGEUPS
T H E
Network Management Card – User Manual
.
Important: Certain UPSs do not support this option
If remaining time is under (0 to 99999 seconds, 180 by default) is the minimum remaining backup time from which the shutdown
sequence is launched.
If battery capacity is under (0 to 100%); this value cannot be less than that of the UPS and is the minimum remaining battery
capacity level from which the shutdown sequence is launched.
Shutdown after (0 to 99999 minutes, not validated by default) is the operating time in minutes left for users after a switch to backup
before starting the shutdown sequence.
Shutdown duration (120 seconds by default) is the time required for complete shutdown of systems when a switch to backup time
is long enough to trigger the shutdown sequences. It is calculated automatically at the maximum of Shutdown duration of
subscribed clients but can be modified in the Advanced mode.
If battery capacity exceeds Minimum battery level to reach before restarting the UPS after utility restoration
Switch Off after (from 0 to 99999, 65535 by default) defines the time during which the outlet is supplied starting from the moment
of utility failure. Caution, this time includes the outlet shutdown duration.
Switch Off if battery capacity under (0 by default) is an extra condition for outlet shutdown that can trigger the shutdown
sequence before the shutdown duration runs out.
Shutdown duration is the time required for complete shutdown of the systems supplied by the outlet when an outlet shutdown
sequence is launched.
It is calculated automatically using the maximum shutdown durations of notified applications on the outlets.
Switch On after (from 0 to 99999, default 65535) is the period between main output startup and startup of the relevant
programmable outlet, therefore outlet startup can be delayed in relation to the main output.
Important: Certain UPSs do not support this option
U N I N T E R R U P T I B L E
shutdown
P O W E R
34003991EN/GA
sequence.
P R O V I D E R
- 22 -