66102 EATON POWERWARE/MGE OFFICE PROTECTION, 66102 Datasheet - Page 46

Network Management Card

66102

Manufacturer Part Number
66102
Description
Network Management Card
Manufacturer
EATON POWERWARE/MGE OFFICE PROTECTION
Datasheet

Specifications of 66102

For Use With
Central UPS Systems That Protect A Complete Network Or For UPS Systems Providing Back-up For Critical Equipment

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
66102-8
Manufacturer:
TE
Quantity:
20 000
Part Number:
66102-8
Manufacturer:
yazaki
Quantity:
17 000
Part Number:
66102-9
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
48 000
Part Number:
66102-9
Manufacturer:
TE
Quantity:
35 000
5
5.1 Set-up of the shutdown parameters
The Network Shutdown Module, on protected server boot, subscribes itself automatically to
data:
During normal operation, the Network Shutdown Module periodically checks its connection with the card.
In case of a major power event, the card sends information to the Network Shutdown Module which reacts according to the situation.
(shutdown order, programmed actions, messages to the administrator and to users via the network)
When the server shuts down, the Network Shutdown Module unsubscribes itself from the
5.1.1 Shutdown criteria managed by the Network Management Card
During an extended power failure, three criteria may cause the server shutdown procedure to be initiated. If several criteria are selected, (See
page
At the end of the shutdown procedure, when all servers have been shut down, the UPS may shut down to avoid unnecessary discharge of its
batteries, depending on its configuration.
T H E
Network Management Card – User Manual
capacity under
Shutdown if
remainig
Time required to shutdown the server (Shutdown Duration, configurable in the "Set-up" menu of each NSM): The card takes into account
IP Address or hostname of the server on which it is installed: So that the card can inform it of power events.
the longest shutdown time of all the Network Shutdown Modules subscribed (This is the Shutdown duration of the
page to manage UPS shutdowns without affecting any of Shutdown Modules connected.
capacity
Shutdown
Battery
Server protection
100%
0%
U N I N T E R R U P T I B L E
parameters), the first criterion encountered will launch the shutdown procedure.
Utility failure
Shutdown after :
P O W E R
34003991EN/GA
Delay before
shutdown
Start of the shutdown sequence
P R O V I D E R
Remaining autonomy
Card parameters
Shutdown duration
If remaining time under
notified
notified applications
applications.
UPS parameters
UPS Shut off
list and sends its essential
Shutdown
t
parameters)
- 46 -