METER STRAIN GAGE 3 1/2-DIGIT

PAXLSG00

Manufacturer Part Number
PAXLSG00
Description
METER STRAIN GAGE 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Strain Gage, Millivolt Meterr
Datasheet

Specifications of PAXLSG00

Measuring Range
±2V
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
3-1/2
Meter Range
0mV To 10mV / 0V To 2V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Signal Input Type
Strain Gage
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
RLC114
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL PAXLSG - PAX LITE STRAIN GAGE METER /
GENERAL DESCRIPTION
pressure, load, force, and other parameters measured with strain gages. The unit
features broad range scaling and can be used with a wide variety of strain gage
resistances and bridge configurations. A built-in excitation source is jumper
selectable for 5 or 10 VDC @ 120 mA maximum, and can power up to four full
350 Ω bridges in load averaging applications. Although designed primarily for
strain-gage indication, the PAXLSG is also ideal for single-ended or differential
millivolt input applications, with full-scale input ranges from 0 to 10 mV thru 0
to 2 VDC. Adjustable scaling and offset allow direct readout in nearly any
engineering unit.
effects to CE requirements, allowing the meter to provide a tough yet reliable
application solution.
DIMENSIONS In inches (mm)
The Model PAXLSG expands the PAX Lite capabilities into the indication of
The meter has a NEMA 4X/IP65 sealed bezel and extensive testing of noise
4
MILLIVOLT METER
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is
2.1" (53.4) H x 5.0" (127) W.
1
SAFETY SUMMARY
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
OPTIONAL CUSTOM UNITS OVERLAY WITH BACKLIGHT
All safety related regulations, local codes and instructions that appear in the
APPLICABLE AS REGULAR MILLIVOLT INDICATOR
(Single-ended or Differential Input)
3 1/2-DIGIT, 0.56" (14.2 mm) HIGH LED READOUT
HIGH SENSITIVITY, 10 mV FULL SCALE
WIDE RANGE GAIN AND OFFSET ADJUSTMENTS
BUILT-IN EXCITATION 5 OR 10 VDC
SELECTABLE DECIMAL POINTS
OVER-RANGE INDICATION
NEMA 4X/IP65 SEALED FRONT BEZEL
installation and operation of the unit.
Read complete instructions prior to
CAUTION: Risk of Danger.
CAUTION: Risk of electric shock.
Bulletin No. PAXLSG-A
Drawing No. LP0571
Released 12/07

PAXLSG00 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLSG - PAX LITE STRAIN GAGE METER / 4 GENERAL DESCRIPTION The Model PAXLSG expands the PAX Lite capabilities into the indication of pressure, load, force, and other parameters measured ...

Page 2

ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications ...

Page 3

G M ENERAL ETER 1. DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment LED, (-) minus sign displayed when voltage is negative. Decimal points inserted before 1st, 2nd, or 3rd least significant digits by DIP switch selection. 2. OVER-RANGE INDICATION: ...

Page 4

I NSTALLING THE Installation The PAX meets NEMA 4X/IP65 requirements when properly installed. The unit is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the unit. ...

Page 5

W IRING THE WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter. All conductors should conform to the meter’s voltage and current ratings. All cabling should conform to appropriate standards of good ...

Page 6

S CALING THE DESCRIPTION OF OPERATION The Pax Lite Strain Gage Indicator (PAXLSG) consists of a digital voltmeter combined with a high-gain, differential input amplifier that has provision for wide range scaling adjustment (shown above). The unit also incorporates ...

Page 7

C ALIBRATING THE There are three different methods that can be used to calibrate the PAXLSG, and the method chosen depends largely on the nature of the application. The three methods are: VOLTAGE CALIBRATION In this method, the transducer ...

Page 8

... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...