PAXLSG00 Red Lion Controls, PAXLSG00 Datasheet - Page 8

METER STRAIN GAGE 3 1/2-DIGIT

PAXLSG00

Manufacturer Part Number
PAXLSG00
Description
METER STRAIN GAGE 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Strain Gage, Millivolt Meterr
Datasheet

Specifications of PAXLSG00

Measuring Range
±2V
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
3-1/2
Meter Range
0mV To 10mV / 0V To 2V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Signal Input Type
Strain Gage
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
RLC114
Red Lion Controls
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
EXAMPLE #1
CALIBRATION
strain gage pressure transducer for pressure indication. The gain required to
display 150 Units @ 20 mV is 150/20, or 7.5 Units/mV. Setting the Coarse
Gain Select Switches S8 and S9 ON, gives a gain range of 6.6 + 3.3, or 9.9
Units/mV maximum, which brackets the required gain. The transducer curve
is zero-based (i.e. zero readout at zero input), and can be easily System
Calibrated. A variable pressure input is applied to the transducer with a “Dead-
Weight Tester” and the Fine Offset is adjusted to give a readout of zero with
no pressure applied. Then 150 PSI is applied, the Coarse and Fine Gain
controls are adjusted for a readout of 150. Pressure is removed, zero is checked
and readjusted with the Fine Offset control if needed. Pressure is varied
between zero and maximum, with the Fine Gain and Offset adjustments
retrimmed as needed until the readout is within tolerance.
EXAMPLE #2 THE MODEL PAXLSG AS A MILLIVOLT
METER
single-ended or differential inputs when connected as shown. Input signals are
referenced to the negative (common) side of the excitation supply (Terminal 3).
Maximum common-mode voltage (for differential input) is 0 to +7 VDC.
EXAMPLE #3
AVERAGE READING
multiple strain gage bridges. In this example, it is used to indicate the quantity
of granular material held in a hopper that is supported by three load cells in a
tripod mounting arrangement. The tare-weight of the empty hopper is about
30% of the full weight, requiring a significant offset for a zero readout when
empty. The PAXLSG is first Voltage-Calibrated (using the known output of the
load cells at the empty and full conditions). Then the unit is installed and fine
trimmed (System Calibration) using known loads.
6.0 A
This illustration depicts a common application using a PAXLSG with a
The PAXLSG can be used as a scaleable millivolt meter and will accept either
The 120 mA excitation output capability of the PAXLSG allows it to operate
PPLICATIONS
PRESSURE READOUT & SYSTEM
MULTIPLE LOAD-CELL INPUT,
The Company warrants the products it manufactures against defects in materials and workmanship
for a period limited to two years from the date of shipment, provided the products have been stored,
handled, installed, and used under proper conditions. The Company’s liability under this limited
warranty shall extend only to the repair or replacement of a defective product, at The Company’s
option. The Company disclaims all liability for any affirmation, promise or representation with
respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against
damages, claims, and expenses arising out of subsequent sales of RLC products or products
containing components manufactured by RLC and based upon personal injuries, deaths, property
damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be
to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those
expressly contained herein. The Customer acknowledges the disclaimers and limitations contained
herein and relies on no other warranties or affirmations.