Read with Auto Precharge command
( RAS = H, CAS = L, WE = H, BS0, BS1 = Bank, A10 = H, A0~A9, A11 = Column Address,
A12=Don't care)
Read operation. When the CAS Latency = 3, the internal precharge starts two cycles before the last
data is output. When the CAS Latency = 2, the internal precharge starts one cycle before the last data
is output (Figure 15). This command must not be interrupted by any other command.
on the TC59SM816BFT/BFTL.
Mode Register Set command
( RAS = L, CAS = L, WE = L, BS0, BS1, A0~A12 = Register Data)
Length in the Mode Register. The default values in the Mode Register after power-up are undefined,
therefore this command must be issued during the power-up sequence. Also, this command can be issued
while all banks are in the idle state.
No-Operation command
( RAS = H, CAS = H, WE = H)
Burst stop command
( RAS = H, CAS = H, WE = L)
Burst operation. During other types of Burst operation, the command is illegal.
Device Deselect command
( CS = H)
Address inputs are ignored. This command is similar to the No-Operation command.
Auto Refresh command
( RAS = L, CAS = L, WE = H, CKE = H, BS0, BS1, A0~A12 = Don’t care)
The Refresh operation must be performed 8192 times within 64 ms. The next command can be issued
after t
banks must be in the idle state. The Auto Refresh operation is equivalent to the CAS -before- RAS
operation in a conventional DRAM.
The Read with Auto Precharge command automatically performs the Precharge operation after the
The A11 input is “Don’t care” on the TC59SM808BFT/BFTL and the A9 and A11 inputs are “Don’t care”
The Mode Register Set command programs the values of CAS latency, Addressing Mode and Burst
The No-Operation command simply performs no operation.
The Burst stop command is used to stop the burst operation. This command is valid during a Full Page
The Device Deselect command disables the command decoder so that the RAS , CAS , WE and
The Auto Refresh command is used to refresh the row address provided by the internal refresh counter.