71M6541D-IGT/F Maxim Integrated Products, 71M6541D-IGT/F Datasheet - Page 14

no-image

71M6541D-IGT/F

Manufacturer Part Number
71M6541D-IGT/F
Description
PMIC Solutions Precision Energy Meter IC
Manufacturer
Maxim Integrated Products
Type
Metering SoCr
Datasheet

Specifications of 71M6541D-IGT/F

Core
8051
Core Architecture
8051
Data Bus Width
8 bit
Data Ram Size
3 KB
Device Million Instructions Per Second
5 MIPS
Interface Type
I2C, ICE, SPI, UART
Maximum Clock Frequency
5 MHz
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Number Of Programmable I/os
30
Number Of Timers
2
On-chip Adc
22 bit
Operating Supply Voltage
3 V to 3.6 V
Package / Case
LQFP-64
Processor Series
8051
Program Memory Size
32 KB
Program Memory Type
Flash
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Figure 5
As seen in
associated with this current channel are not routed to the multiplexer, and are instead transferred digitally
to the 71M6542F via the digital isolation interface and are directly stored in CE RAM.
See
configurations corresponding to
2.2.1 Signal Input Pins
The 71M6541D/F features five ADC inputs. The 71M6542F features six ADC inputs.
IAP-IAN and IBP-IBN are intended for use as current sensor inputs. These four current sensor inputs can be
configured as four single-ended inputs, or can be paired to form two differential inputs. For best
performance, it is recommended to configure the current sensor inputs as differential inputs (i.e., IAP-IAN
and IBP-IBN). The first differential input (IAP-IAN) features a pre-amplifier with a selectable gain of 1 or 8,
and is intended for direct connection to a shunt resistor sensor, and can also be used with a Current
Transformer (CT). The remaining differential pair (i.e., IBP-IBN) may be used with CTs, or may be enabled
to interface to a remote 71M6x01 isolated current sensor providing isolation for a shunt resistor sensor using
a low cost pulse transformer.
The remaining input in the 71M6541D/F (VA) is single-ended, and is intended for sensing the line voltage in
a single-phase meter application using Equation 0 or 1 (see
71M6542F features an additional single-ended voltage sensing input (VB) to support bi-phase applications
using Equation 2. These single-ended inputs are referenced to the V3P3A pin.
All analog signal input pins measure voltage. In the case of shunt current sensors, currents are sensed as a
voltage drop in the shunt resistor sensor. Referring to
the 71M654x (referred to as a ‘local’ shunt sensor) or connected via an isolated 71M6x01 (referred to as a
‘remote’ shunt sensor). In the case of Current Transformers (CT), the current is measured as a voltage
across a burden resistor that is connected to the secondary winding of the CT. Meanwhile, line voltages are
sensed through resistive voltage dividers. The VA and VB pins (VB is available in the 71M6542F only) are
single-ended and their common return is the V3P3A pin.
Pins IAP-IAN can be programmed individually to be differential or single-ended as determined by the
DIFFA_E (I/O RAM 0x210C[4]) control bit. However, for most applications, IAP-IAN are configured as a
differential input to work with a shunt or CT directly interfaced to the IAP-IAN differential input with the
appropriate external signal conditioning components (see
The performance of the IAP-IAN pins can be enhanced by enabling a pre-amplifier with a fixed gain of 8,
using the I/O RAM control bit PRE_E (I/O RAM 0x2704[5]). When PRE_E = 1, IAP-IAN become the inputs
to the 8x pre-amplifier, and the output of this amplifier is supplied to the multiplexer. The 8x amplification
14
Remote
Shunt
Figure 6
IB
shows the 71M6542F multiplexer interface with one local and one remote resistive shunt sensor.
Figure
INN
INP
for the multiplexer timing sequence corresponding to
5, when a remote isolated shunt sensor is connected via the 71M6x01, the samples
71M6x01
Shunt
Local
Figure 5. 71M6542F AFE Block Diagram with 71M6x01
IA
© 2008–2011 Teridian Semiconductor Corporation
SP
SN
VADC10 (VA)
VADC9 (VB)
Figure
IBN
IAN
IBP
IAP
5.
Interface
Isolation
MUX
Digital
Figure
4.2 Direct Connection of Sensors
2.3.4 Meter Equations
3, shunt sensors can be connected directly to
VREF
VADC
Figure
VREF
71M6542F
5. See
VREF
CONVERTER
22
∆Σ ADC
FIR
Figure 38
on page 25). The
22
for the meter
CE RAM
on page 92).
11/5/2010
v1.1