AMIS49587C5871RG ON Semiconductor, AMIS49587C5871RG Datasheet - Page 26

IC MODEM PLC 50/60MHZ 28PLCC

AMIS49587C5871RG

Manufacturer Part Number
AMIS49587C5871RG
Description
IC MODEM PLC 50/60MHZ 28PLCC
Manufacturer
ON Semiconductor
Datasheets

Specifications of AMIS49587C5871RG

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
28-PLCC
Number Of Transmitters
1
Power Supply Requirement
Single
Package Type
PLCC
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
28
Operating Temperature (max)
70C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS49587C5871RG
Manufacturer:
ON
Quantity:
3 400
Part Number:
AMIS49587C5871RG
Manufacturer:
ON Semiconductor
Quantity:
10 000
DESCRIPTION
The Local Transfer and Configuration Commands (LTC)
supplies the following services:
WriteConfigNew_Request (Tag 71h)
Description: The field Data_Config contains the future configuration of the AMIS−49587 (36 bytes). This field is structured
as shown in 7.4.4.
hard or soft reset and also after a power up.
software remains in this state until the configuration is correctly received.
Notice: New Functionality: This command can be used to modify several parameters of the AMIS−49587 at the same time,
even if AMIS−49587 is configured yet. This avoids the use of several successive Write_Db.Request. If the AMIS−49587 is
set yet, some parameters cannot be changed any more and won’t be taken into account. The AMIS−49587 will return a
WriteConfig_Error if the Base Micro tries to modify one of these parameters:
Syntax:
Since the AMIS−49587 has no non−volatile RAM memory, the information about the chip configuration are lost after each
Therefore the AMIS−49587 software waits for a WriteConfig_Request or WriteConfigNew_Request after each reset. The
WriteConfigNew_Request: This command is used by
the Base Micro to set the configuration in the
AMIS−49587. The AMIS−49587 does not need to be
reset before but some parameters cannot be changed
without a reset
WriteConfigNew_Confirm: This command is sent by
the AMIS−49587 to answer to a correct
WriteConfigNew_Request. Its data is the result of the
memory and register reading.
WriteConfigNew_Error: This commands is sent by the
AMIS−49587 to answer to an incorrect
WriteConfigNew_Request. It contains an Error_Code
that indicates which error has been detected.
TestMode_Request: This command is used by the
Base Micro to put the AMIS−49587 in a special mode.
It is used to perform tests on emission level.
Reset_Request: The Reset_Request is used to reset the
AMIS−49587 by software when the Base Micro wants
to do it.
Synchro_Indication: This command is sent by the
AMIS−49587 to inform about the new synchronization
state. Three possibilities could be performed:
synchronization found, synchronization confirmed, and
synchronization lost. Specific data are associated with
each command.
Desynchro_Request: This command is used by the
Base Micro to set the AMIS−49587 in the not
synchronized state and therefore it starts looking for the
synchronization.
Base Micro
Initiator
Frame Format:
<STX>
LOCAL TRANSFER AND CONFIGURATION COMMANDS (LTC)
WriteConfigNew_Request (Data_Config)
Length
Command (arguments)
Not Set
<WriteConfigNew_Request>
http://onsemi.com
26
CONFIGURATION COMMANDS
Description
parameters it needs to work correctly. Most of these
parameters are also accessible by a WriteDB_request.
the previous versions of AMIS−49587, but some additional
functionalities are available. To ensure a perfect
compatibility with the old versions, make sure that:
the version 3, and it enables one more functionality : the
intelligent synchronization. All the new functionalities are
also available with this configuration as well as with
configuration version 3.
The configuration allows to send to AMIS−49587 all the
The configuration version 3 is the same as the one used on
The configuration version 4 enables is a bit different than
the bits corresponding to the number of alarm
repetitions are set to 0 (to disable the alarm
functionality)
the bit corresponding to Bad CRC Frame transmitting is
set to 0 (to disable this functionality)
The bits corresponding to the baudrate are set to 10 for
1200 bauds (since 11 will put the AMIS−49587 at 2400
bauds)
The bits corresponding to the Search Method and SINC
Filter are set to 0
Intelligent synchronization
WriteConfigNew_confirm (Data_Config_Echo)
WriteConfigNew_Error (Error_Code)
Data_Config
Possible Response
CHK