ZMOTIONS200ZCOG Zilog, ZMOTIONS200ZCOG Datasheet - Page 25

no-image

ZMOTIONS200ZCOG

Manufacturer Part Number
ZMOTIONS200ZCOG
Description
KIT DEV ZMOTION MODULE
Manufacturer
Zilog
Series
ZMOTION™r

Specifications of ZMOTIONS200ZCOG

Sensor Type
Motion, PIR (Pyroelectric Infrared)
Sensing Range
-
Interface
USB/Serial
Sensitivity
-
Voltage - Supply
-
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ZMOT1AHH
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
269-4823
Hardware Connection Requirements
PS028801-0311
28-Pin Device Pin 1 (ANA2) is reserved as the analog ADC input from the pyroelectric sensor. In Single
Pyroelectric PIR Sensor #1
ADC V
Pyroelectric PIR Sensor #2
This section describes the required external hardware connection for the ZMOTION MCU
Series. See
matic diagrams showing these connections.
Pins are automatically configured to their required function when the PIR Engine is initial-
ized via the EPIR_INIT macro. The device can be operated in Single Pyro Mode when
supporting one pyroelectric sensor or in Dual Pyro Mode when supporting two pyroelec-
tric sensors. Both of these modes can be operated in Normal or Low Scan Rate modes.
Depending on the application, there can be up to four connection requirements supporting
these modes: one for each of two PIR sensors, one for the ADC and one for the White
Light Detection and Status LED. A description of each of these elements follows in this
section. For a broader description of the White Light Detection component, see the
Light Detection
The signal from the PIR sensor is connected directly to the ANA2 input of the ADC. The
ADC is configured for differential buffered mode by Zilog’s PIR technology. The sensor
signal should be connected directly to the ADC input with no additional signal condition-
ing circuitry unless specified by the pyroelectric sensor manufacturer.
The on-chip V
nected to the positive (+) differential input of the ADC (ANA2), and the V
connected to the negative (–) differential input (ANA3). The 8-pin device provides an
internal connection from V
nal hardware connection is required. The 20- and 28-pin devices require an external con-
nection from the V
In Dual Pyro Mode, the ADC is still used in differential buffered mode (i.e., as is true for
Single Pyro Mode). The signal from the second PIR sensor is connected to ANA3. The
Pyro Mode, Pin 4 (ANA3) must be externally tied to V
be configured as V
In Dual Pyro Mode, which supports 2 pyroelectric sensors, Pin 4 (ANA3) is used for the
second sensor. In this mode the Pin 3 V
other ADC inputs and is therefore available to the application (PB5/V
REF
Appendix A. Example Application Schematics
REF
section on page 19.
is configured for 1V of nominal voltage. The PIR Sensor signal is con-
REF
REF
output signal to the ADC negative (–) (ANA3) input.
output by the PIR Engine when it is enabled.
REF
to ANA3 to support this configuration; therefore, no exter-
REF
signal is not connected externally to any
ZMOTION
Hardware Connection Requirements
REF
on Pin 3 (PB5/ V
on page 53 for example sche-
Product Specification
Intrusion Detection
REF
).
REF
REF
). PB5 will
signal is
White
18