LH28F016SCHR-L95 Sharp Electronics, LH28F016SCHR-L95 Datasheet - Page 14

no-image

LH28F016SCHR-L95

Manufacturer Part Number
LH28F016SCHR-L95
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F016SCHR-L95

Cell Type
NOR
Density
16Mb
Interface Type
Parallel
Boot Type
Not Required
Address Bus
21b
Operating Supply Voltage (typ)
3.3/5V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
3.3/5/12V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7/4.5V
Operating Supply Voltage (max)
3.6/5.5V
Word Size
8b
Number Of Words
2M
Supply Current
50mA
Mounting
Surface Mount
Pin Count
40
Lead Free Status / Rohs Status
Not Compliant
LH28F016SCT
14
FULL STATUS CHECK PROCEDURE
READ STATUS REGISTER
CHECK IF DESIRED
BLOCK ADDRESS
BLOCK ADDRESS
READ STATUS
BLOCK ERASE
DATA (see above)
FULL STATUS
WRITE D0H,
BLOCK ERASE
WRITE 20H,
COMPLETE
SUCCESSFUL
REGISTER
START
SR.7 =
SR.4, 5 =
SR.3 =
SR.1 =
SR.5 =
1
0
0
0
0
0
1
1
1
1
SUSPEND
PROTECT ERROR
COMMAND SEQUENCE
BLOCK ERASE
RANGE ERROR
BLOCK
ERASE
ERROR
DEVICE
NO
V
ERROR
Figure 5. Automated Block Erase Flowchart
PP
YES
SUSPEND
BLOCK
ERASE
LOOP
OPERATION
OPERATION
Repeat for subsequent block erasures.
Full status check can be done after each block erase
or after a sequence of block erasures.
Write FFH after the last operation to place the device
into read array mode.
CSR.5, SR.4, SR.3, and SR.1 are only cleared by the Clear Status
Register Command in cases where multiple blocks are erased
before full status is checked.
If an error is detected, clear the Status Register before attempting a
retry or other error recovery operations.
Standby
Standby
Standby
Standby
Standby
Write
Write
Read
BUS
BUS
COMMAND
COMMAND
Confirm
Erase
Setup
Erase
Data = 20H
Addr = Within Block to be Erased
Data = D0H
Addr = Within Block to be Erased
Status Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
Check SR.3
1 = V
Check SR.1
1 = Device Protect Detect
Check SR.4, 5
Both 1 = Command Sequence Error
Check SR.5
1 = Block Erase Error
RP = V
is Set. Only required for
systems implementing
lock-bit configuration.
PP
Error Detect
IH
COMMENTS
COMMENTS
, Block Lock-Bit
16M Flash Memory
28F016SCT-L95-5
Data Sheet

Related parts for LH28F016SCHR-L95