TXC-04252AIPQ Transwitch Corporation, TXC-04252AIPQ Datasheet - Page 125

TXC-04252AIPQ

Manufacturer Part Number
TXC-04252AIPQ
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04252AIPQ

Pin Count
160
Screening Level
Industrial
Package Type
PQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TXC-04252AIPQ
Manufacturer:
XILINX
Quantity:
8
Part Number:
TXC-04252AIPQ
Manufacturer:
TRANSWITCH
Quantity:
12
Part Number:
TXC-04252AIPQ
Manufacturer:
TRANSWITCH
Quantity:
20 000
Part Number:
TXC-04252AIPQ.CA
Manufacturer:
TRANSWITCH
Quantity:
20 000
0CA Port 4
0CB Port 4
03A Port 1
06A Port 2
09A Port 3
03B Port 1
06B Port 2
09B Port 3
102 Port 1
202 Port 2
302 Port 3
402 Port 4
116 Port 1
216 Port 2
316 Port 3
416 Port 4
Address
Proprietary TranSwitch Corporation Information for use Solely by its Customers.
7-0
7-0
7-0
Bit
7
6
5
4
3
2
Latched Bn
Symbol
Counter
Receive
BnRDIS
BnSIZE
BnNDF
BnLOP
Alarms
An TC
BnAIS
BnRFI
Error
Byte
OEI
An
V4
A Drop Bus Port n Tandem Connection OEI Counter: An 8-bit counter
which counts the number of OEI errors detected in bit 6 in the N2 (Z6)
byte for the TU/VT selected when the tandem connection feature is
enabled. The counter saturates at full count and is cleared when it is
read.
A Drop Bus Port n Receive V4 Byte: When control bit V4EN is 1, the
eight bits in this register position correspond to the V4 byte received in
the TU/VT selected. Bit 7 corresponds to bit 1 in the V4 byte.
Same alarms as the following address locations (7-0), except that these
alarm states are latched.
B Drop Bus Port n TU/VT AIS Alarm: A 1 indicates that an AIS has
been detected in the V1/V2 pointer bytes for the TU/VT selected.
B Drop Bus Port n Loss Of TU/VT Pointer Alarm: A 1 indicates that a
loss of pointer has been detected in the V1/V2 pointer bytes for the
TU/VT selected.
B Drop Bus Port n TU/VT Pointer Size Error Indication: A 1 indicates
that the receive size indicator in the pointer (Bits 5 and 6 in the V1
pointer byte) is not 10 for the TU/VT selected. The detection and recov-
ery time is immediate.
B Drop Bus Port n New Data Flag Indication: A 1 indicates that a New
Data Flag (1001 or 0001/1101/1011/1000) has been detected in the V1
pointer byte for the TU/VT selected (i.e., bits 1-4 in the V1 byte are the
inverse of the normal 0110 pattern or differ in only one bit, with a correct
size indicator and a valid pointer value).
B Drop Bus Port n Remote Server Defect Indication: A 1 indicates
that either a remote server defect alarm has been detected (bits 5, 6 and
7 in K4 (Z7) byte are equal to 101), or an RDI has been detected coming
from older equipment (bit 8 in V5 byte equals 1 when bits 6 and 7 in K4
(Z7) byte are equal to 00 or 11). The number of consecutive events used
for detection and recovery is determined by control bit V5AL10.
B Drop Bus Port n Remote Failure Indication: A 1 indicates that bit 4
in the V5 byte is equal to 1 for the TU/VT selected. The detection and
recovery time is immediate.
- 125 of 148 -
DATA SHEET
Description
Ed. 3, December 2000
TXC-04252
TXC-04252-MB
QE1M

Related parts for TXC-04252AIPQ