TXC-04252AIPQ Transwitch Corporation, TXC-04252AIPQ Datasheet - Page 57

TXC-04252AIPQ

Manufacturer Part Number
TXC-04252AIPQ
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04252AIPQ

Pin Count
160
Screening Level
Industrial
Package Type
PQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TXC-04252AIPQ
Manufacturer:
XILINX
Quantity:
8
Part Number:
TXC-04252AIPQ
Manufacturer:
TRANSWITCH
Quantity:
12
Part Number:
TXC-04252AIPQ
Manufacturer:
TRANSWITCH
Quantity:
20 000
Part Number:
TXC-04252AIPQ.CA
Manufacturer:
TRANSWITCH
Quantity:
20 000
012H: 5
IPOS
X
X
X
0
1
1
1
0
0
0
1
1
1
Proprietary TranSwitch Corporation Information for use Solely by its Customers.
012H: 4
INEG
X
X
X
0
0
0
0
1
1
1
1
1
1
014H: 0
HWDIE
X
X
X
X
0
0
1
0
1
0
1
0
1
Interrupt and Alarm Control Bit Summary
011H: 4
LATEN
1
0
0
0
1
1
1
1
1
1
1
1
1
DATA SHEET
- 57 of 148 -
Interrupt
Mask Bit
X
0
1
1
0
1
1
0
1
1
0
1
1
No alarm event indication, or interrupt register
indication.
Alarm event register sets on positive levels of
an alarm; no software or hardware interrupt
indications.
Alarm event register sets, and software inter-
rupt indication occurs, on positive levels of the
alarm; no hardware interrupt.
Alarm event register sets, and software and
hardware interrupt indications occur, on posi-
tive levels of the alarm.
Alarm event register sets on positive transi-
tions of the alarm; no software or hardware
interrupt indications.
Alarm event register sets, and software inter-
rupt indication occurs, on positive transitions
of the alarm; no hardware interrupt.
Alarm event register sets, and software and
hardware interrupt indications occur, on posi-
tive transitions of the alarm.
Alarm event register sets on negative transi-
tions of the alarm; no software or hardware
interrupt indications.
Alarm event register sets, and software inter-
rupt indication occurs, on negative transitions
of the alarm; no hardware interrupt.
Alarm event register sets, and software and
hardware interrupt indications occur, on nega-
tive transitions of the alarm.
Alarm event register sets on positive and/or
negative transitions of the alarm; no software
or hardware interrupt indications.
Alarm event register sets, and software inter-
rupt indication occurs, on positive and/or neg-
ative transitions of the alarm; no hardware
interrupt.
Alarm event register sets, and software and
hardware interrupt indications occur, on posi-
tive and/or negative transitions of alarm.
Action on an Alarm
Ed. 3, December 2000
TXC-04252
TXC-04252-MB
QE1M

Related parts for TXC-04252AIPQ