TDA5230XT Infineon Technologies, TDA5230XT Datasheet - Page 53

no-image

TDA5230XT

Manufacturer Part Number
TDA5230XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TDA5230XT

Operating Temperature (min)
-40C
Operating Temperature (max)
105C
Operating Temperature Classification
Industrial
Product Depth (mm)
4.4mm
Product Length (mm)
9.7mm
Lead Free Status / Rohs Status
Compliant
Notes to State Diagram Run Mode Self Polling:
1. Modulation Switching: Modulation is set according registers AMT and BMT bits MT.
2. Init: The Receiver will be initialized and the FIFO will be initialized and cleared when
3. FIFO locked: When the signal fifolk is set, the chip enters this state and remains
4. Wait: Wait until symbol synchronization has finished. A loss of symbol
5. Wait: Wait until a start of a data packet (TSI) is detected. All bits received from
6. INIT FIFO: The FIFO will be initialized, if the SFR control bit FSINITFIFO is set
7. Check MID Setup: Check the configuration of the Message ID Unit. Depending on
8. Init MID Scanning Unit: Initialize the Message-ID scanning unit.
9. Wait: Wait until the Message-ID scanning unit has finished the search for a valid
10. Checking ID Scanning Result: The result of a search for a Message ID is checked.
11. EOM Check: The reception of the data frame is completed with EOM. Dependent on
Data Sheet
the SFR control bit INITFIFO is set. Read out the Modulation Type Configuration
(ASK or FSK), which is defined in the SFR control bits AMT/BMT, and set the device
to the configured mode. Set the channel to the correct value, which is defined in the
ARFPLL1/BRFPLL1 register.
there until the signal fifolk is deasserted. In this state, no further data reception is
possible and therefore no SYNC or FSYNC will be generated, even if a data packet
is present in the received data-stream. (More information on the FIFO behavior can
be found in
synchronization always leads into this state, whatever the current state was. This
state is only left, if symbol synchronization could be established on the received data
stream. (More information on the synchronization behavior can be found in
Chapter 2.4.13 Frame
FSYNC until the detection of EOM will be transferred to the FIFO.
the SFR control bit MIDSEN, a Message ID scanning is started or not. If no Message-
ID scanning is selected, the next state is the EOM check state. Otherwise, the
Message ID scanning unit is activated to search for a valid Message-ID.
message ID. All incoming data is stored in the FIFO.
If no valid Message ID was found, a search for a new frame is started. Be aware that
all received bits after FSYNC were stored in the FIFO, even if no Message ID was
found. After a successful search for a Message ID , the next state will be EOM check.
register AEOMC and BEOMC, EOM can be either Sync lost, code violation or
number of received bits.
Chapter 2.4.15 Data
Synchronization).
FIFO).
49
Functional Description
Version 4.0, 2007-06-01
TDA523x