ATTINY861A-XU Atmel, ATTINY861A-XU Datasheet - Page 181

Microcontrollers (MCU) 8K Flash;125B EEPROM 128B SRAM;16 IO Pins

ATTINY861A-XU

Manufacturer Part Number
ATTINY861A-XU
Description
Microcontrollers (MCU) 8K Flash;125B EEPROM 128B SRAM;16 IO Pins
Manufacturer
Atmel
Datasheet

Specifications of ATTINY861A-XU

Core
RISC
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
8 KB
Data Ram Size
512 B
Interface Type
SPI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
16
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-20
Minimum Operating Temperature
- 40 C
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY861A-XUR
Manufacturer:
IDT
Quantity:
1 300
18.7.8
18.7.9
18.7.10
18.7.11
8197B–AVR–01/10
Reading the EEPROM
Programming the Fuse Low Bits
Programming the Fuse High Bits
Programming the Extended Fuse Bits
The algorithm for reading the EEPROM memory is as follows (refer to
on page 177
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 177
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 177
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 177
1. A: Load Command “0000 0011”.
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA.
5. Set OE to “1”.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS1 to “1” and BS2 to “0”. This selects high data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS1 to “0”. This selects low data byte.
1. 1. A: Load Command “0100 0000”.
2. 2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. 3. Set BS1 to “0” and BS2 to “1”. This selects extended data byte.
4. 4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. 5. Set BS2 to “0”. This selects low data byte.
for details on Command and Address loading):
for details on Command and Data loading):
for details on Command and Data loading):
for details on Command and Data loading):
“Programming the Flash”
“Programming the Flash”
“Programming the
“Programming the
181