PEB 3086 H V1.4 Infineon Technologies, PEB 3086 H V1.4 Datasheet - Page 76

no-image

PEB 3086 H V1.4

Manufacturer Part Number
PEB 3086 H V1.4
Description
IC ISDN ACCESS CTRLR TQFP64
Manufacturer
Infineon Technologies
Series
ISAC™r
Datasheet

Specifications of PEB 3086 H V1.4

Function
Subscriber Access Controller
Interface
HDLC, IOM-2, ISDN, Parallel, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-LFQFP
Includes
D-Channel Access Control and Priority Handler, Monitor Channel Handler, Non-Auto Mode, Transparent Mode
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3086HV1.4X
PEB3086HV14XP
SP000007567
ISAC-SX
PEB 3086
Description of Functional Blocks
Any signal except info 2 or 4 detected on the S/T interface.
F6 Synchronized
The receiver has synchronized and detects info 2. Info 3 is transmitted to synchronize
the NT.
F7 Activated
The receiver has synchronized and detects info 4. All user channels are now conveyed
transparently to the IOM-2 interface.
To transfer user channels transparently to the S/T interface either the command AR8 or
AR10 has to be issued and TR_STA.FSYN must be “1” (signal from remote side must
be synchronous).
F8 Lost Framing
The receiver has lost synchronization in the states F6 or F7 respectively.
Unconditional States
Loop A Closed (internal or external)
The ISAC-SX loops back the transmitter to the receiver and activates by transmission of
info 3. The receiver has not yet synchronized.
For a non transparent internal loop the DIS_TX bit of register TR_CONF2 has to be set
to ’1’.
Loop A Activated (internal or external)
The receiver has synchronized to info 3. Data may be sent. The indication “AIL” is output
to indicate the activated state. If the loop is closed internally and the S/T line awake
detector detects any signal on the S/T interface, this is indicated by “RSY”.
Test Mode - SSP
Single alternating pulses are transmitted to the S/T-interface resulting in a frequency of
the fundamental mode of 2 kHz.
Test Mode - SCP
Continuous alternating pulses are transmitted to the S/T-interface resulting in a
frequency of the fundamental mode of 96 kHz.
Data Sheet
76
2003-01-30

Related parts for PEB 3086 H V1.4