PEB 4364 T V1.2 Infineon Technologies, PEB 4364 T V1.2 Datasheet - Page 106

no-image

PEB 4364 T V1.2

Manufacturer Part Number
PEB 4364 T V1.2
Description
IC SLIC VOICE ACCESS PDSO-36
Manufacturer
Infineon Technologies
Series
DuSLICr
Datasheet

Specifications of PEB 4364 T V1.2

Function
Dual Channel Subscriber Line Interface Circuit (DuSLIC)
Interface
IOM-2, PCM
Number Of Circuits
2
Voltage - Supply
3.3 V ~ 5 V
Current - Supply
105mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-PDSO
Includes
DTMF Generator and Decoder, Line Echo Cancellation (LEC), Teletax (TTX) Generation, Universal Tone Detection (UTD)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB4364TV1.2XT
SP000007728
K
CRAM:
Address
LM-AC is a 4-bit nibble which contains K
CG1 is a 4-bit nibble that is calculated by DuSLICOS and which controls the conference
gain (see DuSLICOS byte file). To ensure that CG1 is not changed, please perform a
read/modify/write operation.
Table 24
LM-AC
0
1
:
6
7
The integration function accumulates and sums up the level meter values over a set time
period. The time period from 1*16 ms to 16*16 ms is set by the bits LM-ITIME[3:0] in
register LMCR3. The integration function can be turned on and off by bit LM-EN in
register LMCR1.
The number of samples N
N
The level can be calculated by:
The result registers get frequently updated after an integration period, if bit LM-EN in
register LMCR1 = 1. If the bit LM-ONCE in register LMCR1 is set to 1 then the integration
is executed only once. To start again, bit LM-EN must be changed from 0 to 1.
The level meter result can be transferred to the PCM/IOM-2 Interface, depending on bit
LM2PCM in register LMCR1.
Measurement of Currents via ITAC
To take current measurements via pin ITAC, all feedback loops (IM-filters and TH-filters)
should be disabled. To simplify the formulas, the programmable receive and transmit
gain is disabled.
This is done by setting the following bits:
Preliminary Data Sheet
U dBm0
INTAC
Samples
can be set via coefficient LM-AC:
= LM-ITIME * 8000
=
20
0x34: CG1/LM-AC
K
log
INTAC
LM Result
Setting Table
Samples
-------------------------------------------------------------- -
2
for the integrator is defined by:
K
INT
INTAC.
K
1
½
:
1/64
1/128
106
N
INTAC
Samples
+
3.14
Operational Description
DS3, 2003-07-11
DuSLIC

Related parts for PEB 4364 T V1.2