SC16C2552BIA44,529 NXP Semiconductors, SC16C2552BIA44,529 Datasheet - Page 15

IC UART DUAL W/FIFO 44-PLCC

SC16C2552BIA44,529

Manufacturer Part Number
SC16C2552BIA44,529
Description
IC UART DUAL W/FIFO 44-PLCC
Manufacturer
NXP Semiconductors
Type
Dual UART with 16-byte FIFOsr
Datasheet

Specifications of SC16C2552BIA44,529

Number Of Channels
2, DUART
Package / Case
44-LCC (J-Lead)
Features
2 Channels
Fifo's
16 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.25 V
Supply Current
4.5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-3646-5
935274408529
SC16C2552BIA44-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C2552BIA44,529
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C2552B_3
Product data sheet
Table 8.
Table 9.
Bit
3
(continued)
2
1
0
FCR[7]
0
0
1
1
FIFO Control Register bits description
RCVR trigger levels
Symbol
FCR[2]
FCR[1]
FCR[0]
FCR[6]
0
1
0
1
5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.), with 16-byte FIFOs
Rev. 03 — 12 February 2009
Description
Transmit operation in mode ‘1’: When the SC16C2552B is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1), the TXRDYn pin will be a
logic 1 when the transmit FIFO is completely full. It will be a logic 0 if
one or more FIFO locations are empty.
Receive operation in mode ‘1’: When the SC16C2552B is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1) and the trigger level has been
reached, or a Receive Time-out has occurred, the RXRDY signal at the
MFn pin will go to a logic 0. Once activated, it will go to a logic 1 after
there are no more characters in the FIFO. Note that the AFR register
must be set to the RXRDY mode prior to any possible reading of the
RXRDY signal.
XMIT FIFO reset.
RCVR FIFO reset.
FIFOs enabled.
logic 0 = no FIFO transmit reset (normal default condition)
logic 1 = clears the contents of the transmit FIFO and resets the FIFO
counter logic (the Transmit Shift Register is not cleared or altered).
This bit will return to a logic 0 after clearing the FIFO.
logic 0 = no FIFO receive reset (normal default condition)
logic 1 = clears the contents of the receive FIFO and resets the FIFO
counter logic (the Receive Shift Register is not cleared or altered).
This bit will return to a logic 0 after clearing the FIFO.
logic 0 = disable the transmit and receive FIFO (normal default
condition)
logic 1 = enable the transmit and receive FIFO. This bit must be a ‘1’
when other FCR bits are written to or they will not be
programmed.
RX FIFO trigger level
01
04
08
14
…continued
SC16C2552B
© NXP B.V. 2009. All rights reserved.
15 of 38

Related parts for SC16C2552BIA44,529