MT9075B Mitel Networks Corporation, MT9075B Datasheet - Page 14

no-image

MT9075B

Manufacturer Part Number
MT9075B
Description
E1 Single Chip Transceiver
Manufacturer
Mitel Networks Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9075BL
Quantity:
5 510
Part Number:
MT9075BL
Manufacturer:
ZARLINK
Quantity:
490
Part Number:
MT9075BL
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT9075BL1
Manufacturer:
ZARLINK
Quantity:
5
Part Number:
MT9075BP
Manufacturer:
MT
Quantity:
1 000
Part Number:
MT9075BP
Manufacturer:
MITEL
Quantity:
199
Part Number:
MT9075BP
Manufacturer:
ZARLINK
Quantity:
20 000
MT9075B
one. Bits 5, 7 and 8 (usually designated X) are spare
bits and are normally set to one if not used.
Time slot 16 of the remaining 15 basic frames of the
CAS multiframe (i.e., basic frames 1 to 15) are
reserved for the ABCD signalling bits for the 30
payload channels. The most significant nibbles are
reserved for channels 1 to 15 and the least
significant nibbles are reserved for channels 16 to
30. That is, time slot 16 of basic frame 1 has ABCD
for channel 1 and 16, time slot 16 of basic frame 2
has ABCD for channel 2 and 17, through to time slot
16 of basic frame 15 has ABCD for channel 15 and
30.
MT9075B Access and Control
Register Access
The control and status of the MT9075B is achieved
through a non-multiplexed parallel microprocessor
port. The parallel port may be configured for
Motorola style control signals (by setting pin INT/
MOT low) or Intel style control signals (by setting pin
INT/MOT high).
The controlling microprocessor gains access to
specific registers of the MT9075B through a two step
14
00000001 (01H)
00000010 (02H)
00000011 (03H)
00000100 (04H)
00000101 (05H)
00000110 (06H)
00000111 (07H)
00001000 (08H)
00001001 (09H)
00001010 (0AH)
00001011 (0BH)
00001100 (0CH)
00001101 (0DH)
00001110 (0EH)
00001111 (0FH)
00010000 (10H)
00010001 (11H)
00010010 (12H)
Page Address
D
7
- D
0
Master
Control
Master
Status
Per Channel Transmit Signalling
Per Channel Receive Signalling
Per Time Slot
Control
1 Second Status
unused
HDLC0 Control and Status (TS 0)
HDLC1 Control and Status (TS 16)
Transmit National Bit Buffer
Receive National Bit Buffer
Tx message mode Buffer 0
Tx message mode Buffer 1
Rx message mode Buffer 0
Rx message mode Buffer 1
Register Description
Table 5 - Register Summary
process. First, writing to the internal Command/
Address Register (CAR) selects one of the 18 pages
of control and status registers (CAR address: AC4 =
0, AC3-AC0 = don't care, CAR data D7 - D0 = page
number). Second, each page has a maximum of 16
registers that are addressed on a read or write to a
non-CAR address (non-CAR: address AC4 = 1, AC3-
AC0 = register address, D7-D0 = data). Once a page
of memory is selected, it is only necessary to write to
the CAR when a different page is to be accessed.
See Figures 11 and 12 for timing requirements.
Please note that for microprocessors with read/write
cycles less than 200 ns, a wait state or a dummy
operation
successive read/write operations to the HDLC FIFO
is required.
Table 5 associates the MT9075B control and status
pages with access and page descriptions.
ST-BUS Streams
The ST-BUS stream can also be used to access
channel associated signalling nibbles. CSTo contains
the received channel associated signalling bits (e.g.,
ITU-T R1 and R2 signalling), and when control bit
RPSIG (page 01H, address 1AH) is set to 0, CSTi is
(for
C
Preliminary Information
Processor
programming)
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
between
ST-BUS
Access
CSTo
CSTi
---
---
---
---
---
---
---
---
---
---
---
---
--
two

Related parts for MT9075B