LM3S2730 Luminary Micro, Inc, LM3S2730 Datasheet - Page 38

no-image

LM3S2730

Manufacturer Part Number
LM3S2730
Description
Lm3s2730 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S2730-EQC50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S2730-EQC50-A2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S2730-IBZ50-A2
Manufacturer:
TI
Quantity:
259
Part Number:
LM3S2730-IBZ50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S2730-IBZ50-A2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S2730-IQC50-A2
Manufacturer:
TI
Quantity:
72
Part Number:
LM3S2730-IQC50-A2
Manufacturer:
Texas Instruments
Quantity:
10 000
ARM Cortex-M3 Processor Core
38
of 0 is possible, but has no effect because the SysTick interrupt and COUNTFLAG are activated
when counting from 1 to 0.
Therefore, as a multi-shot timer, repeated over and over, it fires every N+1 clock pulse, where N is
any value from 1 to 0x00FF.FFFF. So, if the tick interrupt is required every 100 clock pulses, 99
must be written into the RELOAD. If a new value is written on each tick interrupt, so treated as single
shot, then the actual count down must be written. For example, if a tick is next required after 400
clock pulses, 400 must be written into the RELOAD.
SysTick Current Value Register
Use the SysTick Current Value Register to find the current value in the register.
SysTick Calibration Value Register
The SysTick Calibration Value register is not implemented.
Bit/Field
Bit/Field
31:24
31:24
23:0
23:0
RELOAD
CURRENT
reserved
reserved
Name
Name
Type
W1C
RO
Type
W1C
RO
Reset
Reset
0
-
0
-
Description
Software should not rely on the value of a reserved bit. To provide compatibility with
future products, the value of a reserved bit should be preserved across a read-modify-write
operation.
Reload
Value to load into the SysTick Current Value Register when the counter reaches 0.
Description
Software should not rely on the value of a reserved bit. To provide compatibility with
future products, the value of a reserved bit should be preserved across a
read-modify-write operation.
Current Value
Current value at the time the register is accessed. No read-modify-write protection is
provided, so change with care.
This register is write-clear. Writing to it with any value clears the register to 0. Clearing
this register also clears the COUNTFLAG bit of the SysTick Control and Status Register.
Preliminary
July 25, 2008

Related parts for LM3S2730