6.9 Programmable baud rate generator
The SC16C850V UART contains a programmable rational baud rate generator that takes
any clock input and divides it by a divisor in the range between 1 and (2
SC16C850V offers the capability of dividing the input frequency by rational divisor. The
fractional part of the divisor is controlled by the CLKPRES register in the First Extra
Register Set.
where:
Prescaler = 1 when MCR[7] is set to 0.
Prescaler = 4 when MCR[7] is set to 1.
A single baud rate generator is provided for the transmitter and receiver. The
programmable Baud Rate Generator is capable of operating with a frequency of up to
80 MHz. To obtain maximum data rate, it is necessary to use full rail swing on the clock
input. The SC16C850V can be configured for internal or external clock operation. For
internal clock operation, an industry standard crystal is connected externally between the
XTAL1 and XTAL2 pins (see
to the XTAL1 pin (see
custom rates (see
The generator divides the input 16 clock by any divisor from 1 to (2
SC16C850V divides the basic external clock by 16. The baud rate is configured via the
CLKPRES, DLL and DLM internal register functions. Customized baud rates can be
achieved by selecting the proper divisor values for the MSB and LSB sections of baud rate
generator.
Programming the baud rate generator registers CLKPRES, DLM (MSB) and DLL (LSB)
provides a user capability for selecting the desired final baud rate. The example in
shows the selectable baud rate table available when using a 1.8432 MHz external clock
input with MCR[7] is 0, and CLKPRES = 0x00.
baud rate
Fig 3.
N is the integer part of the divisor in DLL and DLM registers;
M is the fractional part of the divisor in CLKPRES register;
f
XTAL1
XTAL1
XTAL2
is the clock frequency at XTAL1 pin.
Prescalers and baud rate generator block diagram
=
OSCILLATOR
------------------------------------------------------------------- -
MCR 7
Single UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
Table
Rev. 04 — 14 January 2008
Figure
f
XTAL1
6).
16
Figure
DIVIDE-BY-1
DIVIDE-BY-4
5) to clock the internal baud rate generator for standard or
N
+
----- -
16
M
4). Alternatively, an external clock can be connected
MCR[7] = 0
MCR[7] = 1
GENERATOR
BAUD RATE
(DLL, DLM)
CLKPRES
[3:0]
SC16C850V
16
© NXP B.V. 2008. All rights reserved.
16
1). The
transmitter and
receiver clock
1). The
002aac645
Table 6
11 of 47
(1)