ds26518 Maxim Integrated Products, Inc., ds26518 Datasheet - Page 136

no-image

ds26518

Manufacturer Part Number
ds26518
Description
8-port T1/e1/j1 Transceiver
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26518
Manufacturer:
DS
Quantity:
5 653
Part Number:
DS26518
Manufacturer:
DS
Quantity:
6 203
Part Number:
DS26518
Manufacturer:
DS
Quantity:
1 045
Part Number:
DS26518
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
ds26518-N
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
ds26518GN
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518GN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
ds26518GN+
Manufacturer:
TI
Quantity:
518
Part Number:
ds26518GN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518GN+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
ds26518GN+
Quantity:
347
Part Number:
ds26518GNB1
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
ds26518GNB1
Quantity:
1 228
Company:
Part Number:
ds26518GNB1
Quantity:
1 228
Part Number:
ds26518GNB1+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518NB1+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 4: Receive SLC-96 Synchronizer Enable (RSLC96). See Section
Bits 3 and 2: Out Of Frame Select Bits (OOF[2:1])
Bit 1: Receive RAI Integration Enable (RAIIE). The ESF RAI indication can be interrupted for a period not to
exceed 100ms per interruption (T1.403). In ESF mode, setting RAIIE will cause the RAI status from the DS26518
to be integrated for 200ms.
Bit 0: Receive-Side Remote Alarm Select (RRAIS)
OOF2
0
0
1
1
0 = The SLC-96 synchronizer is disabled.
1 = The SLC-96 synchronizer is enabled.
0 =
1 =
0 = Receive framer detects T1 remote alarm.
1 = Receive Framer detects J1 Remote Alarm.
OOF1
0
1
0
1
7
0
RAI detects when 16 consecutive patterns of 00FF appear in the FDL.
RAI clears when 14 or fewer patterns of 00FF hex out of 16 possible appear in the FDL.
RAI detects when the condition has been present for greater than 200ms.
RAI clears when the condition has been absent for greater than 200ms.
D4—Zeros in bit 2 of all channels.
ESF—00FF pattern in FDL.
D4—A one in the S-bit position of frame 12.
ESF—all ones in FDL.
OUT OF FRAME CRITERIA
2/4 frame bits in error
2/5 frame bits in error
2/6 frame bits in error
2/6 frame bits in error
T1RCR2 (T1 Mode)
Receive Control Register 2
014h + (200h x (n - 1)) : where n = 1 to 8
6
0
5
0
RSLC96
136 of 286
4
0
OOF2
3
0
9.9.4.4
DS26518 8-Port T1/E1/J1 Transceiver
for SLC-96 details.
OOF1
2
0
RAIIE
1
0
RRAIS
0
0