mc68hc908gp32 Freescale Semiconductor, Inc, mc68hc908gp32 Datasheet - Page 185

no-image

mc68hc908gp32

Manufacturer Part Number
mc68hc908gp32
Description
M68hc08 Microcontrollers Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc908gp32CF8
Manufacturer:
MOT
Quantity:
600
Part Number:
mc68hc908gp32CF8
Manufacturer:
MOT
Quantity:
1 000
Part Number:
mc68hc908gp32CFB
Manufacturer:
ON
Quantity:
11
Part Number:
mc68hc908gp32CFB
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908gp32CFB
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
mc68hc908gp32CFBE
Manufacturer:
GAIA
Quantity:
5
Part Number:
mc68hc908gp32CFBR2
Manufacturer:
FREESCALE
Quantity:
69
Part Number:
mc68hc908gp32CP
Manufacturer:
ROCKWELL
Quantity:
201
Part Number:
mc68hc908gp32CP
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
When configured as a slave (SPMSTR = 0), the MODF flag is set if SS goes high during a transmission.
When CPHA = 0, a transmission begins when SS goes low and ends once the incoming SPSCK goes
back to its idle level following the shift of the eighth data bit. When CPHA = 1, the transmission begins
when the SPSCK leaves its idle level and SS is already low. The transmission continues until the SPSCK
returns to its idle level following the shift of the last data bit. (See
In a slave SPI (MSTR = 0), the MODF bit generates an SPI receiver/error CPU interrupt request if the
ERRIE bit is set. The MODF bit does not clear the SPE bit or reset the SPI in any way. Software can abort
the SPI transmission by clearing the SPE bit of the slave.
To clear the MODF flag, read the SPSCR with the MODF bit set and then write to the SPCR register. This
entire clearing mechanism must occur with no MODF condition existing or else the flag is not cleared.
15.8 Interrupts
Four SPI status flags can be enabled to generate CPU interrupt requests.
Freescale Semiconductor
To prevent bus contention with another master SPI after a mode fault error,
clear all SPI bits of the data direction register of the shared I/O port before
enabling the SPI.
Setting the MODF flag does not clear the SPMSTR bit. The SPMSTR bit
has no function when SPE = 0. Reading SPMSTR when MODF = 1 shows
the difference between a MODF occurring when the SPI is a master and
when it is a slave.
When CPHA = 0, a MODF occurs if a slave is selected (SS is at logic 0) and
later unselected (SS is at logic 1) even if no SPSCK is sent to that slave.
This happens because SS at logic 0 indicates the start of the transmission
(MISO driven out with the value of MSB) for CPHA = 0. When CPHA = 1, a
slave can be selected and then later unselected with no transmission
occurring. Therefore, MODF does not occur since a transmission was
never begun.
A logic 1 voltage on the SS pin of a slave SPI puts the MISO pin in a high
impedance state. Also, the slave SPI ignores all incoming SPSCK clocks,
even if it was already in the middle of a transmission.
SPTE
Transmitter empty
SPRF
Receiver full
OVRF
Overflow
MODF
Mode fault
Flag
MC68HC908GP32 Data Sheet, Rev. 10
Table 15-2. SPI Interrupts
SPI transmitter CPU interrupt request
(SPTIE = 1, SPE = 1)
SPI receiver CPU interrupt request
(SPRIE = 1)
SPI receiver/error interrupt request
(ERRIE = 1)
SPI receiver/error interrupt request
(ERRIE = 1)
NOTE
NOTE
NOTE
Request
15.5 Transmission
Formats.)
Interrupts