ncn6004a ON Semiconductor, ncn6004a Datasheet - Page 16

no-image

ncn6004a

Manufacturer Part Number
ncn6004a
Description
Dual Sam/sim Interface Integrated Circuit
Manufacturer
ON Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NCN6004A
Manufacturer:
INTERSIL
Quantity:
101
Part Number:
NCN6004A
Manufacturer:
MOTOROLA
Quantity:
87
Part Number:
ncn6004aFTBR2
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
ncn6004aFTBR2G
Manufacturer:
ON
Quantity:
1 944
Part Number:
ncn6004aFTBR2G
Manufacturer:
ON
Quantity:
2 524
Part Number:
ncn6004aFTBR2G
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
ncn6004aFTBR2G
Manufacturer:
ON/安森美
Quantity:
20 000
*The STATUS register is not affected when the NCN6004A operates in any of the programming mode.
SYSTEM STATES UPON UPON START−UP
Table 3. Status Pins Data
Table 4. Operating Conditions Upon Start−up
Initialized conditions upon start−up are depicted by bold characters in Table 2 and Table 4.
STATE
CRD_VCC_A
CRD_VCC_B
CRD_CLK_A
CRD_CLK_B
CRD_CLK_A
CRD_CLK_B
CRD_CLK_A
CRD_CLK_B
CLOCK Route
(HEX)
00
01
02
03
00
01
02
03
PGM
1
1
1
1
1
1
1
1
Figure 5. Reading ANLG_VCC Status (monitoring ANLG_VCC input voltage)
A3
X
X
X
X
X
X
X
X
Direct (CLK_A → A, CLK_B → B)
Vbat STATUS
Vbat_OK
START (clock is valid)
START (clock is valid)
The input power supply voltage monitoring applies to the card selected.
A2
3.30 V
2.70 V
2.10 V
2.00 V
Low Speed Slope
Low Speed Slope
X
X
X
X
X
X
X
X
Vbat
1/1 Ratio
1/1 Ratio
3.0 V
3.0 V
A1
0
0
1
1
0
0
1
1
A0
0
1
0
1
0
1
0
1
http://onsemi.com
NCN6004A
CARD_SEL
Typical ANLG_VCC Operating Voltage
Min. ANLG_VCC Under Voltage
Max. ANLG_VCC Under Voltage
X
X
16
1
1
1
0
0
0
pin 44, the system will run into a parallel mode
(MUX_MODE = L)
(MUX_MODE = H). It is not possible to change the logic
state once the system is running.
the internal pull up resistors (I/O_A and I/O_B line) will be
either connected to ANLG_VCC voltage (EN_RPU = H) or
disconnected (EN_RPU = L). It is not possible to change this
operating condition once the system is running.
Depending upon the logic state at turn on present on
Similarly, depending upon the logic state present pin 45,
Vcc_V
VCC_OK Fail = High
CRD_VCC_A In Range
Pass = High Fail =Low
CRD_VCCA Overloaded
Pass = High Fail = Low
CRD_DET_A
Card Present = High
bat
STATUS #A
_OK Pass = Low
or
a
VCC_OK Pass = Low
VCC_OK Fail = High
CRD_VCC_B In Range
Pass = High Fail =Low
CRD_VCC_B Overloaded
Pass = High Fail = Low
CRD_DET_A
Card Present = High
multiplexed
STATUS #B
mode

Related parts for ncn6004a