EPF10K10 ETC, EPF10K10 Datasheet - Page 18

no-image

EPF10K10

Manufacturer Part Number
EPF10K10
Description
EMBEDDED PROGRAMMABLE LOGIC FAMILY
Manufacturer
ETC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPF10K100A3NBC356
Manufacturer:
ALTERA
Quantity:
21
Part Number:
EPF10K100ABC256-1
Manufacturer:
ALTERA
Quantity:
50
Part Number:
EPF10K100ABC356
Quantity:
442
Part Number:
EPF10K100ABC356
Manufacturer:
ALTERA
0
Part Number:
EPF10K100ABC356-1
Manufacturer:
ALTERA
Quantity:
8 831
Part Number:
EPF10K100ABC356-1
Manufacturer:
ALTERA30
Quantity:
205
Part Number:
EPF10K100ABC356-1
Manufacturer:
ALTERA
0
Part Number:
EPF10K100ABC356-1
0
Part Number:
EPF10K100ABC356-1N
Manufacturer:
ST
Quantity:
230
Part Number:
EPF10K100ABC356-2
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EPF10K100ABC356-2
Manufacturer:
ALTERA
0
Part Number:
EPF10K100ABC356-2N
Manufacturer:
Altera
Quantity:
10 000
18
FLEX 10K Embedded Programmable Logic Family Data Sheet
LE Operating Modes
The FLEX 10K LE can operate in the following four modes:
Each of these modes uses LE resources differently. In each mode, seven
available inputs to the LE—the four data inputs from the LAB local
interconnect, the feedback from the programmable register, and the
carry-in and cascade-in from the previous LE—are directed to different
destinations to implement the desired logic function. Three inputs to the
LE provide clock, clear, and preset control for the register. Quartus and
MAX+PLUS II software packages, in conjunction with parameterized
functions such as LPM and DesignWare functions, automatically chooses
the appropriate mode for common functions such as counters, adders,
and multipliers. If required, the designer can also create special-purpose
functions which use a specific LE operating mode for optimal
performance.
The architecture provides a synchronous clock enable to the register in all
four modes. Quartus and MAX+PLUS II software packages can set DATA1
to enable the register synchronously, providing easy implementation of
fully synchronous designs.
Figure 9
Normal mode
Arithmetic mode
Up/down counter mode
Clearable counter mode
shows the LE operating modes.