P89V51RD2 Philips Semiconductors, P89V51RD2 Datasheet - Page 29

no-image

P89V51RD2

Manufacturer Part Number
P89V51RD2
Description
8-bit 80C51 5 V low power 64 kB Flash microcontroller with 1 kB RAM
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P89V51RD2BN
Manufacturer:
TDK
Quantity:
12
Part Number:
P89V51RD2BN
Manufacturer:
NXP
Quantity:
1 236
Part Number:
P89V51RD2BN
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
P89V51RD2BNЈ¬112
Manufacturer:
NXP
Quantity:
67
Part Number:
P89V51RD2FA
Manufacturer:
BI
Quantity:
230
Part Number:
P89V51RD2FA
Quantity:
6 250
Part Number:
P89V51RD2FA
Manufacturer:
NXP
Quantity:
1 331
Part Number:
P89V51RD2FA
Manufacturer:
NXP
Quantity:
200
Part Number:
P89V51RD2FA
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
P89V51RD2FA,512
Manufacturer:
Freescale
Quantity:
312
Part Number:
P89V51RD2FA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
P89V51RD2FBC
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
P89V51RD2FBC
Quantity:
26
Part Number:
P89V51RD2FBC,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
9397 750 12964
Product data
Table 17:
Table 18:
Bit addressable; Reset value: 00H
Table 19:
Table 20:
Not bit addressable; Reset value: XX000000B
RCLK+TCLK CP/RL2
0
0
0
1
X
Bit
7
6
5
4
3
2
1
0
Bit
Symbol
Bit
Symbol
Timer 2 operating mode
T2CON - Timer/Counter 2 control register (address C8H) bit allocation
T2CON - Timer/Counter 2 control register (address C8H) bit description
T2MOD - Timer 2 mode control register (address C9H) bit allocation
Symbol
TF2
EXF2
RCLK
TCLK
EXEN2
TR2
C/T2
CP/RL2
TF2
7
7
-
0
1
0
X
X
Rev. 01 — 01 March 2004
EXF2
6
6
-
Description
Timer 2 overflow flag set by a Timer 2 overflow and must be
cleared by software. TF2 will not be set when either RCLK or
TCLK = 1 or when Timer 2 is in Clock-out Mode.
Timer 2 external flag is set when Timer 2 is in capture, reload or
baud-rate mode, EXEN2 = 1 and a negative transition on T2EX
occurs. If Timer 2 interrupt is enabled EXF2 = 1 causes the CPU to
vector to the Timer 2 interrupt routine. EXF2 must be cleared by
software.
Receive clock flag. When set, causes the UART to use Timer 2
overflow pulses for its receive clock in modes 1 and 3. RCLK = 0
causes Timer 1 overflow to be used for the receive clock.
Transmit clock flag. When set, causes the UART to use Timer 2
overflow pulses for its transmit clock in modes 1 and 3. TCLK = 0
causes Timer 1 overflows to be used for the transmit clock.
Timer 2 external enable flag. When set, allows a capture or reload
to occur as a result of a negative transition on T2EX if Timer 2 is
not being used to clock the serial port. EXEN2 = 0 causes Timer 2
to ignore events at T2EX.
Start/stop control for Timer 2. A logic ‘1’ enables the timer to run.
Timer or counter select. (Timer 2)
Capture/Reload flag. When set, captures will occur on negative
transitions at T2EX if EXEN2 = 1. When cleared, auto-reloads will
occur either with Timer 2 overflows or negative transitions at T2EX
when EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this bit is
ignored and the timer is forced to auto-reload on Timer 2 overflow.
0 = internal timer (f
1 = External event counter (falling edge triggered; external
clock’s maximum rate = f
TR2
1
1
1
1
0
RCLK
5
5
-
TCLK
4
4
-
T2OE
0
0
1
0
X
osc
8-bit microcontrollers with 80C51 core
/6)
OSC
EXEN2
3
3
/12
-
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Mode
16-BIT auto reload
16-bit capture
Programmable Clock-Out
Baud rate generator
off
P89V51RD2
TR2
2
2
-
T2OE
C/T2
1
1
CP/RL2
DCEN
29 of 75
0
0

Related parts for P89V51RD2