EDD5108AFTA_06 ELPIDA [Elpida Memory], EDD5108AFTA_06 Datasheet - Page 30

no-image

EDD5108AFTA_06

Manufacturer Part Number
EDD5108AFTA_06
Description
512M bits DDR SDRAM
Manufacturer
ELPIDA [Elpida Memory]
Datasheet
Auto Precharge
Read with auto-precharge
The precharge is automatically performed after completing a read operation. The precharge starts tRPD (BL/2)
cycle after READA command input. tRAP specification for READA allows a read command with auto precharge to be
issued to a bank that has been activated (opened) but has not yet satisfied the tRAS (min) specification. A column
command to the other active bank can be issued the next cycle after the last data output. Read with auto-precharge
command does not limit row commands execution for other bank.
note(Notes.*14)‘.
Write with auto-precharge
The precharge is automatically performed after completing a burst write operation. The precharge operation is
started (1 + BL/ 2 + tWR) cycles after WRITA command issued. A column command to the other banks can be
issued the next cycle after the internal precharge command issued. Write with auto-precharge command does not
limit row commands execution for other bank. Refer to the ‘Read with Auto-Precharge Enabled, Write with Auto-
Precharge Enabled’ section. Refer to ‘Function truth table and related note(Notes.*14)‘.
Data Sheet E0699E50 (Ver. 5.0)
Note: Internal auto-precharge starts at the timing indicated by "
Note: Internal auto-precharge starts at the timing indicated by "
Command
Command
DQS
/CK
DQS
DM
DQ
CK
/CK
DQ
CK
ACT
ACT
tRAP (min) = tRCD (min)
tRCD (min)
NOP
WRITA
tRAS (min)
READA
Read with auto-precharge
Burst Write (BL = 4)
in1
BL/2 cycles
in2
tRPD
1 + BL/2 + tWR cycles
tAC,tDQSCK
30
".
in3
".
NOP
in4
EDD5108AFTA, EDD5116AFTA
out0
NOP
Refer to ‘Function truth table and related
out1 out2
tRP (min)
out3
tRP
ACT
BL = 4
ACT

Related parts for EDD5108AFTA_06