MAX1245ACAP Maxim Integrated, MAX1245ACAP Datasheet - Page 14

no-image

MAX1245ACAP

Manufacturer Part Number
MAX1245ACAP
Description
Analog to Digital Converters - ADC Integrated Circuits (ICs)
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1245ACAP

Number Of Channels
8/4
Architecture
SAR
Conversion Rate
100 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Snr
70 dB
Interface Type
4-Wire (SPI, Microwire, QSPI, TMS320)
Operating Supply Voltage
2.375 V to 3.3 V
Maximum Operating Temperature
+ 70 C
Package / Case
SSOP-20
Maximum Power Dissipation
640 mW
Minimum Operating Temperature
0 C
Number Of Converters
1
Factory Pack Quantity
66
Voltage Reference
2.048 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1245ACAP
Manufacturer:
MAXIM/美信
Quantity:
20 000
The fastest the MAX1245 can run is 15 clocks per conver-
sion with CS held low between conversions. Figure 11a
shows the serial-interface timing necessary to perform a
conversion every 15 SCLK cycles in external clock mode.
If CS is low and SCLK is continuous, guarantee a start bit
by first clocking in 16 zeros.
Most microcontrollers require that conversions occur in
multiples of eight SCLK clocks; 16 clocks per conversion
will typically be the fastest that a microcontroller can
drive the MAX1245. Figure 11b shows the serial-inter-
face timing necessary to perform a conversion every 16
SCLK cycles in external clock mode.
__________ Applications Information
When power is first applied, and if SHDN is not pulled
low, internal power-on reset circuitry activates the
MAX1245 in internal clock mode, ready to convert with
SSTRB = high. After the power supplies have stabi-
lized, the internal reset time is 10µs, and no conver-
sions should be performed during this phase. SSTRB is
high on power-up and, if CS is low, the first logical 1 on
+2.375V, Low-Power, 8-Channel,
Serial 12-Bit ADC
Figure 11a. External Clock Mode, 15 Clocks/Conversion Timing
Figure 11b. External Clock Mode, 16 Clocks/Conversion Timing
14
DOUT
SCLK
DIN
CS
SSTRB
DOUT
SCLK
______________________________________________________________________________________
DIN
CS
S
CONTROL BYTE 0
S
1
CONTROL BYTE 0
Power-On Reset
8
B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
CONVERSION RESULT 0
CONVERSION RESULT 0
S
1
DIN will be interpreted as a start bit. Until a conversion
takes place, DOUT shifts out zeros.
The MAX1245’s automatic power-down mode can save
considerable power when operating at speeds below
the maximum sampling rate. Figure 13 shows the aver-
age supply current as a function of the sampling rate.
You can save power by placing the converter in a low-
current shutdown state between conversions.
Select power-down via bits 1 and 0 of the DIN control
byte with SHDN high (Tables 1 and 4). Pull SHDN low at
any time to shut down the converter completely. SHDN
overrides bits 1 and 0 of the control byte (Table 5).
Power-down mode turns off all chip functions that draw
quiescent current, reducing I
Figures 12a and 12b illustrate the various power-down
sequences in both external and internal clock modes.
Software power-down is activated using bits PD1 and PD0
of the control byte. As shown in Table 4, PD1 and PD0
CONTROL BYTE 1
S
CONTROL BYTE 1
8
B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
CONVERSION RESULT 1
DD
Software Power-Down
typically to 1.2µA.
B11 B10 B9 B8
CONVERSION RESULT 1
S
1
CONTROL BYTE 2
Power-Down
• • •
• • •
• • •
• • •

Related parts for MAX1245ACAP