C8051F314R Silicon Labs, C8051F314R Datasheet - Page 152

no-image

C8051F314R

Manufacturer Part Number
C8051F314R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F314R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
LQFP-32
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
29
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
C8051F310/1/2/3/4/5/6/7
152
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bits1–0: SMBCS1-SMBCS0: SMBus Clock Source Selection.
ENSMB
R/W
Bit7
ENSMB: SMBus Enable.
This bit enables/disables the SMBus interface. When enabled, the interface constantly mon-
itors the SDA and SCL pins.
0: SMBus interface disabled.
1: SMBus interface enabled.
INH: SMBus Slave Inhibit.
When this bit is set to logic 1, the SMBus does not generate an interrupt when slave events
occur. This effectively removes the SMBus slave from the bus. Master Mode interrupts are
not affected.
0: SMBus Slave Mode enabled.
1: SMBus Slave Mode inhibited.
BUSY: SMBus Busy Indicator.
This bit is set to logic 1 by hardware when a transfer is in progress. It is cleared to logic 0
when a STOP or free-timeout is sensed.
EXTHOLD: SMBus Setup and Hold Time Extension Enable.
This bit controls the SDA setup and hold times according to Table 14.2.
0: SDA Extended Setup and Hold Times disabled.
1: SDA Extended Setup and Hold Times enabled.
SMBTOE: SMBus SCL Timeout Detection Enable.
This bit enables SCL low timeout detection. If set to logic 1, the SMBus forces Timer 3 to
reload while SCL is high and allows Timer 3 to count when SCL goes low. If Timer 3 is con-
figured in split mode (T3SPLIT is set), only the high byte of Timer 3 is held in reload while
SCL is high. Timer 3 should be programmed to generate interrupts at 25 ms, and the
Timer 3 interrupt service routine should reset SMBus communication.
SMBFTE: SMBus Free Timeout Detection Enable.
When this bit is set to logic 1, the bus will be considered free if SCL and SDA remain high for
more than 10 SMBus clock source periods.
These two bits select the SMBus clock source, which is used to generate the SMBus bit
rate. The selected device should be configured according to Equation 14.1.
SMBCS1
SFR Definition 14.1. SMB0CF: SMBus Clock/Configuration
INH
R/W
Bit6
0
0
1
1
SMBCS0
BUSY
Bit5
R
0
1
0
1
EXTHOLD SMBTOE SMBFTE SMBCS1
R/W
Bit4
Timer 2 High Byte Overflow
Timer 2 Low Byte Overflow
SMBus Clock Source
Timer 0 Overflow
Timer 1 Overflow
Rev. 1.7
R/W
Bit3
R/W
Bit2
R/W
Bit1
SFR Address:
SMBCS0 00000000
R/W
Bit0
0xC1
Reset Value

Related parts for C8051F314R