C8051F314R Silicon Labs, C8051F314R Datasheet - Page 154

no-image

C8051F314R

Manufacturer Part Number
C8051F314R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F314R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
LQFP-32
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
29
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
C8051F310/1/2/3/4/5/6/7
154
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bit1:
Bit0:
MASTER TXMODE
Bit7
R
MASTER: SMBus Master/Slave Indicator.
This read-only bit indicates when the SMBus is operating as a master.
0: SMBus operating in Slave Mode.
1: SMBus operating in Master Mode.
TXMODE: SMBus Transmit Mode Indicator.
This read-only bit indicates when the SMBus is operating as a transmitter.
0: SMBus in Receiver Mode.
1: SMBus in Transmitter Mode.
STA: SMBus Start Flag.
Write:
0: No Start generated.
1: When operating as a master, a START condition is transmitted if the bus is free (If the bus
is not free, the START is transmitted after a STOP is received or a timeout is detected). If
STA is set by software as an active Master, a repeated START will be generated after the
next ACK cycle.
Read:
0: No Start or repeated Start detected.
1: Start or repeated Start detected.
STO: SMBus Stop Flag.
Write:
0: No STOP condition is transmitted.
1: Setting STO to logic 1 causes a STOP condition to be transmitted after the next ACK
cycle. When the STOP condition is generated, hardware clears STO to logic 0. If both STA
and STO are set, a STOP condition is transmitted followed by a START condition.
Read:
0: No Stop condition detected.
1: Stop condition detected (if in Slave Mode) or pending (if in Master Mode).
ACKRQ: SMBus Acknowledge Request
This read-only bit is set to logic 1 when the SMBus has received a byte and needs the ACK
bit to be written with the correct ACK response value.
ARBLOST: SMBus Arbitration Lost Indicator.
This read-only bit is set to logic 1 when the SMBus loses arbitration while operating as a
transmitter. A lost arbitration while a slave indicates a bus error condition.
ACK: SMBus Acknowledge Flag.
This bit defines the out-going ACK level and records incoming ACK levels. It should be writ-
ten each time a byte is received (when ACKRQ=1), or read after each byte is transmitted.
0: A "not acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if
in Receiver Mode).
1: An "acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if in
Receiver Mode).
SI: SMBus Interrupt Flag.
This bit is set by hardware under the conditions listed in Table 14.3. SI must be cleared by
software. While SI is set, SCL is held low and the SMBus is stalled.
Bit6
R
SFR Definition 14.2. SMB0CN: SMBus Control
STA
R/W
Bit5
STO
R/W
Bit4
ACKRQ ARBLOST
Rev. 1.7
Bit3
R
Bit2
R
ACK
R/W
Bit1
SFR Address:
R/W
Bit0
SI
0xC0
Bit Addressable
00000000
Reset Value