KSZ8851-16MLL-EVAL Micrel Inc, KSZ8851-16MLL-EVAL Datasheet - Page 66

BOARD EVALUATION KSZ8851-16MLL

KSZ8851-16MLL-EVAL

Manufacturer Part Number
KSZ8851-16MLL-EVAL
Description
BOARD EVALUATION KSZ8851-16MLL
Manufacturer
Micrel Inc
Series
LinkMD®r
Datasheets

Specifications of KSZ8851-16MLL-EVAL

Main Purpose
Interface, Ethernet Controller (PHY and MAC)
Embedded
No
Utilized Ic / Part
KSZ8851-16MLL
Primary Attributes
1 Port, 100BASE-TX/10BASE-T
Secondary Attributes
8/16-Bit Interface, LinkMD Cable Diagnostics
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
576-3292
Port 1 Status Register (0xF8 – 0xF9): P1SR
This register contains the PHY port status for the chip function.
August 2009
Micrel, Inc.
Bit
4
3
2
1
0
Bit
15
14
13
12-11
10
9
8
7
6
5
4
Default
1
1
1
1
1
Default
1
0
0
0
0
0
0
1
0
0
0
R/W
RW
RW
RW
RW
RW
R/W
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Description
Advertised flow control capability
1 = advertise flow control (pause) capability.
0 = suppress flow control (pause) capability from
transmission to link partner.
Advertised 100BT full-duplex capability
1 = advertise 100BT full-duplex capability.
0 = suppress 100BT full-duplex capability from
transmission to link partner.
Advertised 100BT half-duplex capability
1 = advertise 100BT half-duplex capability.
0 = suppress 100BT half-duplex capability from
transmission to link partner.
Advertised 10BT full-duplex capability
1 = advertise 10BT full-duplex capability.
0 = suppress 10BT full-duplex capability from
transmission to link partner.
Advertised 10BT half-duplex capability
1 = advertise 10BT half-duplex capability.
0 = suppress 10BT half-duplex capability from
transmission to link partner.
Description
HP_mdix
1 = HP Auto MDI-X mode.
0 = Micrel Auto MDI-X mode.
Reserved
Polarity Reverse
1 = polarity is reversed.
0 = polarity is not reversed.
Reserved
Operation Speed
1 = link speed is 100Mbps.
0 = link speed is 10Mbps.
Operation Duplex
1 = link duplex is full.
0 = link duplex is half.
Reserved
MDI-X status
1 = MDI.
0 = MDI-X.
AN Done
1 = AN done.
0 = AN not done.
Link Good
1= link good.
0 = link not good.
Partner flow control capability
1 = link partner flow control (pause) capable.
0 = link partner not flow control (pause) capable.
66
Bit is same as:
Bit 10 in P1ANAR
Bit 8 in P1ANAR
Bit 7 in P1ANAR
Bit 6 in P1ANAR
Bit 5 in P1ANAR
Bit is same as:
Bit 5 in P1MBCR
Bit 5 in P1MBSR
Bit 2 in P1MBSR
Bit 10 in P1ANLPR
KSZ8851-16MLL/MLLI
M9999-083109-2.0

Related parts for KSZ8851-16MLL-EVAL