EVB9303 SMSC, EVB9303 Datasheet - Page 154

EVALUATION BOARD FOR LAN9303

EVB9303

Manufacturer Part Number
EVB9303
Description
EVALUATION BOARD FOR LAN9303
Manufacturer
SMSC
Datasheets

Specifications of EVB9303

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9303
Primary Attributes
3 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
Full Duplex and HP Auto-MDIX Support, 10BASE-T and 100BASE-TX
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1095
Revision 1.4 (07-07-10)
13.2.4.2
BITS
31:7
6
5
4
3
2
1
RESERVED
Port 2 Backpressure Enable (BP_EN_2)
This bit enables/disables the generation of half-duplex backpressure on
switch Port 2.
0: Disable backpressure
1: Enable backpressure
Port 2 Current Duplex (CUR_DUP_2)
This bit indicates the actual duplex setting of switch Port 2.
0: Full-Duplex
1: Half-Duplex
Port 2 Current Receive Flow Control Enable (CUR_RX_FC_2)
This bit indicates the actual receive flow setting of switch Port 2.
0: Flow control receive is currently disabled
1: Flow control receive is currently enabled
Port 2 Current Transmit Flow Control Enable (CUR_TX_FC_2)
This bit indicates the actual transmit flow setting of switch Port 2.
0: Flow control transmit is currently disabled
1: Flow control transmit is currently enabled
Port 2 Full-Duplex Receive Flow Control Enable (RX_FC_2)
When the MANUAL_FC_2 bit is set, or Auto-Negotiation is disabled, this bit
enables/disables the detection of full-duplex Pause packets on switch Port 2.
0: Disable flow control receive
1: Enable flow control receive
Port 2 Full-Duplex Transmit Flow Control Enable (TX_FC_2)
When the MANUAL_FC_2 bit is set, or Auto-Negotiation is disabled, this bit
enables/disables full-duplex Pause packets to be generated on switch Port
2.
0: Disable flow control transmit
1: Enable flow control transmit
Port 2 Manual Flow Control Register (MANUAL_FC_2)
This read/write register allows for the manual configuration of the switch Port 2 flow control. This
register also provides read back of the currently enabled flow control settings, whether set manually
or Auto-Negotiated. Refer to
information.
Note: The flow control values in the PHY_AN_ADV_2 register (see
within the PHY are not affected by the values of this register.
Offset:
1A4h
DESCRIPTION
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Section 6.2.3, "Flow Control Enable Logic," on page 62
DATASHEET
154
Size:
32 bits
Section 13.3.2.5, on page
TYPE
R/W
R/W
R/W
SMSC LAN9303/LAN9303i
RO
RO
RO
RO
Note 13.10
Note 13.10
for additional
DEFAULT
Note 13.8
Note 13.9
Note 13.9
Note 13.9
Datasheet
-
199)