EVB9303 SMSC, EVB9303 Datasheet - Page 46

EVALUATION BOARD FOR LAN9303

EVB9303

Manufacturer Part Number
EVB9303
Description
EVALUATION BOARD FOR LAN9303
Manufacturer
SMSC
Datasheets

Specifications of EVB9303

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9303
Primary Attributes
3 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
Full Duplex and HP Auto-MDIX Support, 10BASE-T and 100BASE-TX
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1095
Revision 1.4 (07-07-10)
4.2.4.1
a load, an external pull-up or pull-down resistor should be used to augment the internal resistor to
ensure that it reaches the required voltage level prior to latching. The internal resistor can also be
overridden by the addition of an external resistor.
Note: The system designer must guarantee that configuration strap pins meet the timing
Soft-Straps
Soft-strap values are latched on the release of POR or nRST and are overridden by values from the
EEPROM Loader (when an EEPROM is present). These straps are used as direct configuration values
or as defaults for CPU registers. Some, but not all, soft-straps have an associated pin. Those that do
not have an associated pin have a tie off default value. All soft-strap values can be overridden by the
EEPROM Loader.
Straps which have an associated pin are also fully defined in
Configuration," on page
the operation of the EEPROM Loader and the loading of strap values. The use of the term “configures”
in the “Description” section of
term “Affects” means the value of the register bit is determined by the strap value and some other
condition(s).
Upon setting the
issuing a RELOAD command via the
to their original latched (non-overridden) values if an EEPROM is no longer attached or has been
erased. The associated pins are not re-sampled. (i.e. The value latched on the pin during the last POR
or nRST will be used, not the value on the pin during the digital reset or RELOAD command issuance).
If it is desired to re-latch the current configuration strap pin values, a POR or nRST must be issued.
requirements specified in
If configuration strap pins are not at the correct voltage level prior to being latched, the device
may capture incorrect strap values.
Digital Reset (DIGITAL_RST)
Table 4.2
23. Refer to
provides a list of all soft-straps and their associated pin or default value.
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Table 4.2
Section 14.5.2, "Reset and Configuration Strap Timing," on page
DATASHEET
Section 8.4, "EEPROM Loader," on page 113
EEPROM Command Register
means the register bit is loaded with the strap value, while the
46
bit in the
Reset Control Register (RESET_CTL)
Chapter 3, "Pin Description and
(E2P_CMD), these straps return
SMSC LAN9303/LAN9303i
for information on
Datasheet
or upon
351.