MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 103

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
D.1
© 2009 Microchip Technology Inc.
FIRMWARE VERSIONS
Appendix D. 50/60 Hz Meter Operation
There are two versions of firmware for the meter due to the quasi-synchronous
sampling scheme employed by the dsPIC33F firmware. The design covers the
frequency of rated frequency ±2.5 Hz.
To change the rated frequency, just change the definition in the beginning of
cacul.h - #define STD_FREQ 50.0.
This is provided for download from Microchip’s website, file names and checksums
below.
At the same time you need to change the crystal to provide clock for metering IC.
TABLE D-1:
Line Frequency
50 Hz
60 Hz
ENERGY METER REFERENCE DESIGN
FIRMWARE FILES
Firmware Name
MCP3909 / DSPIC33F 3-PHASE
PM_1_50.ZIP
PM_1_60.ZIP
Hex File Checksum
TBD
TBD
DS51723A-page 103
YXX VALUE
3.857 MHz
TBD

Related parts for MCP3909RD-3PH1