MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 54

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
6.4
REGISTER 6-1:
6.5
DS51723A-page 54
bit 7
Legend:
R = Readable bit
-n = Value at POR
bit 7
bit 6
bit 5:4
bit 3:2
bit 1:0
CPO
R-0
STATUS REGISTER
HARMONIC CONTENT COMMAND
CPO: Current Phase Order
1 = Problem Detected
0 = Normal
VPO: Voltage Phase Order
1 = Problem Detected
0 = Normal
PHC_S: Phase C Status
11 = High Votage
10 = No Input
01 = Low Voltage
00 = Normal
PHB_S: Phase C Status
11 = High Votage
10 = No Input
01 = Low Voltage
00 = Normal
PHA_S: Phase C Status
11 = High Votage
10 = No Input
01 = Low Voltage
00 = Normal
VPO
R-0
This register contains the gain register.
STATUS REGISTER
TABLE 6-8:
TABLE 6-9:
0xFF, 0x00
0xFF, 0x00
START
START
W = Writable bit
‘1’ = Bit is set
PHC_S1
R-0
Command
Command
PC TO METER (7 BYTES)
METER RESPONSE (134 BYTES)
0x43
0x44
PHC_S0
R-0
Length
Length
Data
0x00
Data
0x80
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
PHB_S1
R-0
Data Field
Data Field
128 bytes
0x00
PHB_S0
R-0
Check Sum
Check Sum
© 2009 Microchip Technology Inc.
x = Bit is unknown
XX
XX
PHA_S1
R-0
STOP
STOP
PHA_S0
0xE0
0xE0
R-0
bit 0

Related parts for MCP3909RD-3PH1