STEVAL-IAS001V1 STMicroelectronics, STEVAL-IAS001V1 Datasheet - Page 14

BOARD EVAL ST7FLITE39/STM1403

STEVAL-IAS001V1

Manufacturer Part Number
STEVAL-IAS001V1
Description
BOARD EVAL ST7FLITE39/STM1403
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-IAS001V1

Main Purpose
Reference Design, Security Keypad (MCU Based)
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST7FLITE39, STM1403
Primary Attributes
4x3 Key Matrix, Intrusion Detection
Secondary Attributes
Graphical User Interface, RS-232 Interface
Processor To Be Evaluated
ST7LITE39F2
Interface Type
RS-232
Silicon Manufacturer
ST Micro
Silicon Core Number
ST7Lite39F2 And STM1403
Kit Application Type
Reference Design
Application Sub Type
Security Keypad
Kit Contents
Board CD Docs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6398
STEVAL-IAS001V1
Running the security door application
Note:
2.3
14/27
1.
2.
3.
4.
5.
The system prevents the admin password from being deleted. Any attempt to do so is
handled as ‘user code not found’ and the red error LED glows for approximately 12 seconds
and the system exits admin mode.
Administrator password reset through board
In the event that the administrator password is forgotten, it can be reset to the default value
of "00000". This is done as follows:
Press the
The red error LED starts flashing, indicating that you are in administrator mode.
Enter the admin password, within 1 minute.
Press the
Enter the user code to be deleted, within 1 minute.
Press the
Deleting a user event is logged in the EEPROM and can be seen through the GUI.
If the admin password is valid, the red error LED flashes 6-times.
If the admin password is wrong, the red error LED glows for approximately 12
seconds. After this the system exits admin mode. Also, this event is logged in the
EEPROM as "Invalid Password: Error" and can be seen through the GUI.
If the admin password is not entered within 1 minute, the red error LED glows for
approximately 12 seconds. After this the system exits admin mode.
If
deleted. If yes, the red error LED flashes 6 times. Otherwise, (no user code to
delete) the red error LED flashes 30 times and the system exits admin mode.
If an incorrect key is pressed, the red error LED glows for approximately 12
seconds. After this the system exits admin mode.
If no key is pressed within 1 minute, the red error LED glows for approximately 12
seconds. After this the system exits admin mode.
If a 5-digit user code is entered, the system checks if it exists. If it exists, the red
error LED flashes 6 times. If not found, the red error LED glows for approximately
12 seconds and the system exits admin mode.
If a user code is not entered within 1 minute, the red error LED glows for
approximately 12 seconds. After this the system exits admin mode.
If
system is updated and the red error LED flashes 18 times. After this the system
exits admin mode.
If an incorrect key is pressed, the red error LED glows for approximately 12
seconds. After this the system exits admin mode. No user code is deleted from the
system.
If no key is pressed within 1 minute, the red error LED glows for approximately 12
seconds. After this the system exits admin mode. No user code is deleted from the
system.
#
*
is pressed, the system checks if there is any user code in the system to be
is pressed, this is confirmation by the user to delete the user code. The
*
#
*
key, within 1 minute
key.
key, within 1 minute
UM0408