STEVAL-ISQ002V1 STMicroelectronics, STEVAL-ISQ002V1 Datasheet - Page 14

BOARD EVAL BASED ON ST72264G1

STEVAL-ISQ002V1

Manufacturer Part Number
STEVAL-ISQ002V1
Description
BOARD EVAL BASED ON ST72264G1
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-ISQ002V1

Main Purpose
Interface, PMBus
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST72F264
Primary Attributes
The PMBus™ Interface Using the ST7 I2C Peripheral
Secondary Attributes
Firmware in C Language
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6423

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ISQ002V1
Manufacturer:
STMicroelectronics
Quantity:
1
PMBus commands and source code
14/43
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Description
SMBus transaction type
Number of data bytes
Command name
Command code
Description
SMBus transaction type
Number of data bytes
Command name
Command code
Description
SMBus transaction type
Number of data bytes
Command name
Command code
Description
SMBus transaction type
Number of data bytes
Command name
Command code
Description
VOUT_OV_WARN_LIMIT (continued)
VOUT_UV_WARN_LIMIT
IOUT_OC_FAULT_LIMIT
IOUT_OC_WARN_LIMIT
OT_FAULT_LIMIT
Doc ID 13286 Rev 2
The VOUT_OV_WARN_LIMIT command sets the
value of the output voltage at the sense or output
pins that causes an output voltage high warning.
This value is typically less than the output
overvoltage threshold.
Read/ Write word
2
VOUT_UV_WARN_LIMIT
43h
The VOUT_UV_WARN_LIMIT command sets the
value of the output voltage at the sense or output
pins that causes an output voltage low warning.
This value is typically greater than the output
undervoltage fault threshold
Read/ Write word
2
IOUT_OC_FAULT_LIMIT
46h
The IOUT_OC_FAULT_LIMIT command sets the
value of the sense output current, in amps (literal
format), that causes an overcurrent fault.
Read/ Write word
2
IOUT_OC_WARN_LIMIT
4Ah
The IOUT_OV_WARN_LIMIT command sets the
value of the output current that causes an output
overcurrent warning.
Read/ Write word
2
OT_FAULT_LIMIT
4Fh
The OT_FAULT_LIMIT command sets the value
of the sense temperature, in °C (literal format),
that causes an overtemperature fault
AN2511