STEVAL-IHM010V1 STMicroelectronics, STEVAL-IHM010V1 Datasheet - Page 37

KIT IGBT PWR MODULE CTRL ST7MC

STEVAL-IHM010V1

Manufacturer Part Number
STEVAL-IHM010V1
Description
KIT IGBT PWR MODULE CTRL ST7MC
Manufacturer
STMicroelectronics
Type
Motor / Motion Controllers & Driversr
Datasheets

Specifications of STEVAL-IHM010V1

Main Purpose
Power Management, Motor Control
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST7FMC2S4
Primary Attributes
3-Ph Brushless BLDC, AC & 3-Ph AC Induction (ACIM) Motors
Secondary Attributes
Graphic User Interface, 4 Pots for Runtime Settings, Start/Stop and Reset Buttons
Input Voltage
5 V
Product
Power Management Modules
Silicon Manufacturer
ST Micro
Core Architecture
ARM
Core Sub-architecture
ARM7TDMI
Silicon Core Number
ST7
Silicon Family Name
ST7MCx
Kit Contents
Board
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
ST7MC
Other names
497-8400
UM0430
7.5.2
7.5.3
7.5.4
7.5.5
7.5.6
Specific jumper settings
To set up the power board jumper, follow the instructions in the power board user manual.
Open the J5 jumper on the control board. Keep J2 of the control board open.
LED behavior after power on
Turn on the power supply. For this demonstration the power supply output voltage should be
set to 220 Vac and current limitation of the power supply should be set to 10 amp.
After power on the control board LED behavior should be the following:
Setting of potentiometer
Run the motor (LED behavior)
During any state: idle, start, run or brake, blinking of the red LED indicates a fault condition.
A fault condition is due to one of the following conditions:
Changing real-time parameters
The real-time parameters can be changed using the potentiometers of the control board.
Table 13
Green and red LEDs blink alternatingly signaling that the firmware has started to run.
After a while the green LED stays on to indicate "idle state"
Set P1 potentiometer to full counter clockwise.
Set P2 potentiometer to full counter clockwise.
Push the Start/Stop button
After pushing the button the LEDs toggle from green to red to indicate "RUN state"
Rotate the P2 potentiometer clockwise while the motor start to run.
Hardware overcurrent: current flowing inside motor reaches a value greater than max
current allowed 4 amp (see
GUI)
Over voltage: bus voltage reaches a value greater than 280 Vac.
Over temperature: onboard temperature sensor measures a temperature greater than
60°.
Startup failed: no signal from the tachometer sensor is present at the end of startup.
Motor stalled: during the run of the motor, no tachometer sensor signal has been
observed.
explains the potentiometer functionality based on the driving strategy.
Section 7.4.10: Changing the maximum current allowed by
Motor control demonstration
37/48