CAN-100 Fujitsu Semiconductor America Inc, CAN-100 Datasheet - Page 88

BOARD EVAL RS232 100QFP

CAN-100

Manufacturer Part Number
CAN-100
Description
BOARD EVAL RS232 100QFP
Manufacturer
Fujitsu Semiconductor America Inc
Series
FRr
Type
MCUr
Datasheets

Specifications of CAN-100

Contents
Board, BLDC Motor, Cables, Power Supply
For Use With/related Products
MB91F267N
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
865-1102

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CAN-100
Manufacturer:
Fujitsu Semiconductor America
Quantity:
135
CAN employs the multi-master communication system, so any node can start communication. But, the
number of communication sessions actually allowed on one bus is only one. Each node is cyclically
checking whether the bus is the status of transmission. When there is no transmission on the bus,
communication is started, but if more than one node starts transmission, they conflict. Against this, CAN
performs arbitration to give priority to one with a lower ID for transmission. This section describes the
arbitration.
The arbitration is carried out by comparison between the ID and the bus level by bit as shown in “Figure
5-4 Operation of the arbitration”. Bit 10 to 7 of Node 1 and Node 2 are the same as the bus level. This
indicates that both Node 1 and Node 2 are transmitting signals. But, Bit 6 of Node 1 is set to “0” and that
of Node 2 is set to “1”. The bus level is “0”, so Node 2 recognizes that the frame is not of its own
communication and stops the transmission immediately. Node 1 keeps on transmitting. After Node 1 ends
its communication, Node 2 resumes transmission.
The bus status is determined according to the logical product of IDs, so “0” is prior to “1”. This means
that a lower ID takes priority.
A practical communication flow shown in “Figure 5-5 Example of arbitration among nodes” is as
described below. First, Node 1 and Node 2 starts transmission simultaneously. The arbitration results in
5.2.2
Node 1
Node 2
Bus level
Arbitration
Figure 5-4 Operation of the arbitration
Node 1 is the same as the bus level, so Node 2 stops
transmission.
Arbitration field
- 88 -
Control field
AN07-00180-3E

Related parts for CAN-100