101-1108 Rabbit Semiconductor, 101-1108 Datasheet - Page 16

KIT EMBEDDED PLC APPLICATION

101-1108

Manufacturer Part Number
101-1108
Description
KIT EMBEDDED PLC APPLICATION
Manufacturer
Rabbit Semiconductor
Series
Coyoter
Type
MPU Moduler
Datasheet

Specifications of 101-1108

Contents
BL2500, ISaGRAF V3.50, Embedded PLC software kernel, ISaGRAF Programming Cable and Documentation
Processor To Be Evaluated
Rabbit 3000
Interface Type
RS-232, Ethernet
For Use With/related Products
BL2500
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
316-1120
EMBEDDED
Open the ISaGRAF_V3.50\Sentinel folder (located in the root directory of the CD-ROM) and double-
click on Setup.exe. Follow the on-screen instructions to install the driver. After the installation is
completed, connect the dongle to a parallel or USB port and open the License Manager (Start menu →
Programs → ISaGRAF 3.5 → Licensing). On the Selected Components list, the ISaGRAF 3 Hardware
license will be shown active.
2.4 BL2500 CONNECTIONS
2.4.1 Connect a Power Supply
1. Connect the AC adapter to header J2 on the BL2500 as shown in Figure 1. Match the friction lock tab
2. Plug the AC Adapter. DS1 (yellow) and DS2 (red) LEDs indicate the Firmware Kernel status after the
2.4.2 Connect an Ethernet Cable
The BL2500 that comes in the
and configured. The default factory configuration is:
OEM Technology Solutions
on the friction-lock connector to the back of header J2 on the BL2500 as shown. The friction-lock
connector will only fit one way. Plug in the AC adapter.
Application Kits sold outside North America or Australia include a friction-lock connector that can be
connected to header J2 on the BL2500. Connect the leads from your power supply to the friction-lock
connector to preserve the polarity indicated in the figure. The power supply should deliver 8 – 40 VDC
at 500 mA.
board has been powered up. If after 10 seconds DS2 (red) is turned off and DS1 (yellow) starts
blinking, the Firmware Kernel is licensed and active.
If DS2 (red) remains turned on during more than 10 seconds, it indicates that Kernel requires
licensing. If DS1 and DS2 are off after powered-up, it indicates that the board has no EMBEDDED
PLC Firmware Kernel loaded. In both cases, contact your local distributor.
Modbus Slave Number = 1
Use Modbus TCP
IP Address = 192.168.1.100
PLC BL2500 User’s Manual
EMBEDDED
Figure 1: Power Supply Connection
PLC Application Kit has the Firmware Kernel loaded, licensed
Getting Started
Page 10